Effects of Metal Implants on Computed Tomographic Attenuation Values in the Canine Antebrachium: A Cadaveric Study

Computed tomography (CT) of postoperative orthopedic cases can yield valuable clinical information, especially when radiographic findings are equivocal. Image quality can be adversely affected by the presence of metallic implants. Several studies evaluating metal artifacts on CT have been published in humans, but studies involving veterinary patients are limited. This study aimed to assess attenuation value changes caused by metal artifacts on adjacent anatomical structures. This prospective cadaveric study included 20 Greyhound cadaver forelimbs. The limbs underwent CT before and after application of a 316L stainless steel plate and screws along the cranial surface of the radius. Attenuation values of the radial cortex, medulla, and caudal soft tissues were compared before and after implant placement. Five anatomical sites along the antebrachium were selected for comparison: (1) at the level of a non-filled plate hole, (2) along the plate between 2 screws, (3) at the edge of the plate, and (4) 1 and (5) 3 cm proximal to the plate, respectively. The attenuation values between pre- and post-implant images were significantly different in the radial medulla, cranial, and caudal cortices at Sites 2 and 3, and in the cranial radial cortex at Site 1. No significant differences were found in the antebrachial caudal soft tissues at any site, nor at any region at Sites 4 and 5. The presence of stainless steel implants significantly affects the attenuation values of adjacent cortical and medullary bone, which may lead to image interpretation errors.

Authors

Institutions

Publication Details

Journal
Veterinary Radiology & Ultrasound
Published
2025-10-17
DOI
https://doi.org/10.1111/vru.70103
Primary Topic
Advanced X-ray and CT Imaging
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Effects of Metal Implants on Computed Tomographic Attenuation Values in the Canine Antebrachium: A Cadaveric Study

Cliona Skelly, Marie‐Pauline Maurin, Giulia Dalla Serra, Irene Hernández‐Girón et al.
Veterinary Radiology & Ultrasound
Advanced X-ray and CT Imaging
article

Effects of Metal Implants on Computed Tomographic Attenuation Values in the Canine Antebrachium: A Cadaveric Study

Cliona Skelly, Marie‐Pauline Maurin, Giulia Dalla Serra, Irene Hernández‐Girón, Sèamus Hoey
article en

Abstract

Computed tomography (CT) of postoperative orthopedic cases can yield valuable clinical information, especially when radiographic findings are equivocal. Image quality can be adversely affected by the presence of metallic implants. Several studies evaluating metal artifacts on CT have been published in humans, but studies involving veterinary patients are limited. This study aimed to assess attenuation value changes caused by metal artifacts on adjacent anatomical structures. This prospective cadaveric study included 20 Greyhound cadaver forelimbs. The limbs underwent CT before and after application of a 316L stainless steel plate and screws along the cranial surface of the radius. Attenuation values of the radial cortex, medulla, and caudal soft tissues were compared before and after implant placement. Five anatomical sites along the antebrachium were selected for comparison: (1) at the level of a non-filled plate hole, (2) along the plate between 2 screws, (3) at the edge of the plate, and (4) 1 and (5) 3 cm proximal to the plate, respectively. The attenuation values between pre- and post-implant images were significantly different in the radial medulla, cranial, and caudal cortices at Sites 2 and 3, and in the cranial radial cortex at Site 1. No significant differences were found in the antebrachial caudal soft tissues at any site, nor at any region at Sites 4 and 5. The presence of stainless steel implants significantly affects the attenuation values of adjacent cortical and medullary bone, which may lead to image interpretation errors.

Veterinary Radiology & UltrasoundVol. 66(6)
University College Dublin (IE)
Openalex Percentile: Top 71%
Advanced X-ray and CT Imaging
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Effects of Metal Implants on Computed Tomographic Attenuation Values in the Canine Antebrachium: A Cadaveric Study — Cliona Skelly, Marie‐Pauline Maurin, et al. · Veterinary Radiology & Ultrasound (2025) | TGRS Research Map | TGRS