Effectiveness of Preformed Myofunctional Devices in the Treatment of Malocclusions: A Pilot Study

Introduction: Preformed myofunctional appliances are increasingly being studied in orthodontics and are typically used to address oral function anomalies as well as malocclusions and development defects of the jaws. The aim of this study is to evaluate the efficacy of a protocol based on the use of preformed devices and myofunctional therapy for the correction of malocclusions. Materials and Methods: A retrospective study was conducted to evaluate the effectiveness of a preformed myofunctional devices in correcting certain orthodontic problems related to overbite, overjet, and cross-bite. Thirty-six patients in the mixed dentition phase were analyzed along with their clinical records, photos, and scans. Overjet, Overbite, and Crossbite were measured by analyzing the files exported in the Standard Tesselation Language format (Stl) of patients’ arches using Zeiss Inspect® software (version 2025.1.0.1985). Results: The data analysis reveals a statistically significant improvement in the correction of deep bite, overjet, and crossbite. Specifically, regarding the overbite (OVB), the initial measurement at T0 showed an average of 2.52 mm. The average OVB decreased to 1.73 mm at T1. The overjet had an initial average of 3.59 mm at T0, which decreased to 1.77 mm at T1. In this case as well, the difference between the measurements at T0 and T1 was statistically significant. Finally, the crossbite was evaluated by comparing the difference between mandibular and maxillary intermolar widths at T0 and T1. The average difference decreased from 5.84 mm at T0, to 1.68 mm at T1. Conclusions: Preformed myofunctional appliances represent a valid alternative in interceptive orthodontics for correcting and preventing orthodontic issues, especially of mild severity.

Authors

Institutions

Publication Details

Journal
Applied Sciences
Published
2025-10-17
DOI
https://doi.org/10.3390/app152011153
Primary Topic
Laser Applications in Dentistry and Medicine
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Effectiveness of Preformed Myofunctional Devices in the Treatment of Malocclusions: A Pilot Study

Luca Levrini, Andrea Carganico, Stefano Saran, Nicola Giannotta et al.
Applied Sciences
Laser Applications in Dentistry and Medicine
article

Effectiveness of Preformed Myofunctional Devices in the Treatment of Malocclusions: A Pilot Study

Luca Levrini, Andrea Carganico, Stefano Saran, Nicola Giannotta, Alessandro Deppieri, Vincenzo Giorgino, Silvia Giorgino
article en

Abstract

Introduction: Preformed myofunctional appliances are increasingly being studied in orthodontics and are typically used to address oral function anomalies as well as malocclusions and development defects of the jaws. The aim of this study is to evaluate the efficacy of a protocol based on the use of preformed devices and myofunctional therapy for the correction of malocclusions. Materials and Methods: A retrospective study was conducted to evaluate the effectiveness of a preformed myofunctional devices in correcting certain orthodontic problems related to overbite, overjet, and cross-bite. Thirty-six patients in the mixed dentition phase were analyzed along with their clinical records, photos, and scans. Overjet, Overbite, and Crossbite were measured by analyzing the files exported in the Standard Tesselation Language format (Stl) of patients’ arches using Zeiss Inspect® software (version 2025.1.0.1985). Results: The data analysis reveals a statistically significant improvement in the correction of deep bite, overjet, and crossbite. Specifically, regarding the overbite (OVB), the initial measurement at T0 showed an average of 2.52 mm. The average OVB decreased to 1.73 mm at T1. The overjet had an initial average of 3.59 mm at T0, which decreased to 1.77 mm at T1. In this case as well, the difference between the measurements at T0 and T1 was statistically significant. Finally, the crossbite was evaluated by comparing the difference between mandibular and maxillary intermolar widths at T0 and T1. The average difference decreased from 5.84 mm at T0, to 1.68 mm at T1. Conclusions: Preformed myofunctional appliances represent a valid alternative in interceptive orthodontics for correcting and preventing orthodontic issues, especially of mild severity.

Applied SciencesVol. 15(20)
University of Insubria (IT), Ospedale di Circolo di Busto Arsizio (IT)
Openalex Percentile: Top 57%
Laser Applications in Dentistry and Medicine
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.