HVDC Receiving-End Power Grid Multi-Resource Coordinated Transient Voltage Emergency Control Technology Based on Transient Voltage Similarity

This study addresses the issues related to the inaccurate assessment of transient voltage stability margins and the limited participation of resources involved in regulation during high-voltage direct current (HVDC) receiving-end grid faults under high-penetration new energy integration. This paper proposes a method for transient voltage emergency control at the HVDC receiving-end grid, utilizing a multi-resource approach based on transient voltage similarity partitioning with a multiple-two-element notation criterion. First, the transient voltage stability margin and the new energy transient off-grid margin index, based on the multiple-two-element notation criterion, are introduced. Second, a grid partitioning scheme is employed, which clusters nodes based on the similarity of their transient voltage features, and the impact of multiple resources on the transient voltage stability of the HVDC receiving-end system is analyzed using trajectory sensitivity. On this basis, a multi-resource optimization model for transient voltage emergencies is established with the aim of minimizing the control cost, considering the transient voltage stability, off-grid new energy, and other safety evaluation constraints, in order to coordinate multiple resources participating in transient voltage control until the stability requirements are met. Finally, the validity of the proposed control scheme is verified using the improved frequency stability benchmark test system (Chinese Society for Electrical Engineering—Frequency Stability, CSEE-FS). The research results demonstrate that the scheme proposed in this study can be utilized to accurately assess the transient voltage stability and off-grid potential of renewable energy units following failure at the HVDC receiving-end system. Additionally, it can reasonably partition the grid based on transient operating conditions while fully exploiting the potential of multiple resources within the faulted partition to control transient voltage emergencies in the grid.

Authors

Institutions

Publication Details

Journal
Electronics
Published
2025-10-17
DOI
https://doi.org/10.3390/electronics14204090
Citations
1
Primary Topic
High-Voltage Power Transmission Systems
Type
article
Field-Weighted Citation Impact
0.73

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

HVDC Receiving-End Power Grid Multi-Resource Coordinated Transient Voltage Emergency Control Technology Based on Transient Voltage Similarity

Qiankun Guo, Xiongguang Zhao, Jianghui Xi, Ling Xu et al.
1 citations
Electronics
High-Voltage Power Transmission Systems
0.73
article

HVDC Receiving-End Power Grid Multi-Resource Coordinated Transient Voltage Emergency Control Technology Based on Transient Voltage Similarity

Qiankun Guo, Xiongguang Zhao, Jianghui Xi, Ling Xu, Xiaodong Yu
article en
1 citations

Abstract

This study addresses the issues related to the inaccurate assessment of transient voltage stability margins and the limited participation of resources involved in regulation during high-voltage direct current (HVDC) receiving-end grid faults under high-penetration new energy integration. This paper proposes a method for transient voltage emergency control at the HVDC receiving-end grid, utilizing a multi-resource approach based on transient voltage similarity partitioning with a multiple-two-element notation criterion. First, the transient voltage stability margin and the new energy transient off-grid margin index, based on the multiple-two-element notation criterion, are introduced. Second, a grid partitioning scheme is employed, which clusters nodes based on the similarity of their transient voltage features, and the impact of multiple resources on the transient voltage stability of the HVDC receiving-end system is analyzed using trajectory sensitivity. On this basis, a multi-resource optimization model for transient voltage emergencies is established with the aim of minimizing the control cost, considering the transient voltage stability, off-grid new energy, and other safety evaluation constraints, in order to coordinate multiple resources participating in transient voltage control until the stability requirements are met. Finally, the validity of the proposed control scheme is verified using the improved frequency stability benchmark test system (Chinese Society for Electrical Engineering—Frequency Stability, CSEE-FS). The research results demonstrate that the scheme proposed in this study can be utilized to accurately assess the transient voltage stability and off-grid potential of renewable energy units following failure at the HVDC receiving-end system. Additionally, it can reasonably partition the grid based on transient operating conditions while fully exploiting the potential of multiple resources within the faulted partition to control transient voltage emergencies in the grid.

ElectronicsVol. 14(20)
State Grid Corporation of China (China) (CN), Tsinghua University (CN)
State Grid Corporation of China
Openalex Percentile: Top 22%
High-Voltage Power Transmission Systems
0.73
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.