Cubosomes─colloidal dispersions of lipid inverted bicontinuous cubic phases─are promising nanosystems for advanced drug delivery applications. Here, we report on a microfluidic hydrodynamic flow-focusing approach for solvent exchange that enables the preparation of cubosomes with tunable size. The approach involves a preliminary step where the lipid phytantriol, the main building block, is first dissolved in ethanol to create a precursor solution. This precursor is subsequently flowed through the central channel of a cross-shaped microfluidic device, where it is focused by two lateral streams of water containing the stabilizer Pluronic F127. As water and ethanol mix, the polarity shift forces phytantriol to self-assemble into cubosomes, while the laminar-flow conditions imposed by the microchannels provide controlled mixing conditions. By adjusting the flow rate ratio (<i>Q</i><sub><i>R</i></sub>) between the water-F127 side streams and the phytantriol-ethanol precursor, we control the width of the precursor stream─the region through which solvent molecules exchange. This manipulation thus directly governs the mixing time, influencing the kinetics of lipid self-assembly, which ultimately determines particle size. This technique allows for the tuning of cubosome sizes from 195 nm down to 125 nm, with size decreasing monotonically as <i>Q<sub>R</sub></i> increases and the polydispersity index remaining in the low-to-moderate range. Although variability is still significant, largely due to pumping instability and the use of a commercial microfluidic device not specifically designed for this application, the trends are statistically significant for every precursor-concentration series (<i>p</i> ≤ 0.011). Further customization of the apparatus is expected to improve reproducibility and scalability. The results obtained with this microfluidic method differ markedly from those obtained by bulk solvent exchange, which shows only a weak and generally nonsignificant trend toward larger particle size at higher dilution ratios.

Authors

Institutions

Publication Details

Journal
Langmuir
Published
2025-10-17
DOI
https://doi.org/10.1021/acs.langmuir.5c03488
Primary Topic
Innovative Microfluidic and Catalytic Techniques Innovation
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Microfluidic Flow-Focusing for Size-Controlled Formation of Cubosomes

Ulf Olsson, Bruno F. B. Silva, Cláudia Botelho, Celso J. O. Ferreira et al.
Langmuir
Innovative Microfluidic and Catalytic Techniques Innovation
article

Microfluidic Flow-Focusing for Size-Controlled Formation of Cubosomes

Ulf Olsson, Bruno F. B. Silva, Cláudia Botelho, Celso J. O. Ferreira, Marco Fornasier, Maria Margarida Barros, M. Elisabete C.D. Real Oliveira, Alexandre Chícharo
article en

Abstract

Cubosomes─colloidal dispersions of lipid inverted bicontinuous cubic phases─are promising nanosystems for advanced drug delivery applications. Here, we report on a microfluidic hydrodynamic flow-focusing approach for solvent exchange that enables the preparation of cubosomes with tunable size. The approach involves a preliminary step where the lipid phytantriol, the main building block, is first dissolved in ethanol to create a precursor solution. This precursor is subsequently flowed through the central channel of a cross-shaped microfluidic device, where it is focused by two lateral streams of water containing the stabilizer Pluronic F127. As water and ethanol mix, the polarity shift forces phytantriol to self-assemble into cubosomes, while the laminar-flow conditions imposed by the microchannels provide controlled mixing conditions. By adjusting the flow rate ratio (<i>Q</i><sub><i>R</i></sub>) between the water-F127 side streams and the phytantriol-ethanol precursor, we control the width of the precursor stream─the region through which solvent molecules exchange. This manipulation thus directly governs the mixing time, influencing the kinetics of lipid self-assembly, which ultimately determines particle size. This technique allows for the tuning of cubosome sizes from 195 nm down to 125 nm, with size decreasing monotonically as <i>Q<sub>R</sub></i> increases and the polydispersity index remaining in the low-to-moderate range. Although variability is still significant, largely due to pumping instability and the use of a commercial microfluidic device not specifically designed for this application, the trends are statistically significant for every precursor-concentration series (<i>p</i> ≤ 0.011). Further customization of the apparatus is expected to improve reproducibility and scalability. The results obtained with this microfluidic method differ markedly from those obtained by bulk solvent exchange, which shows only a weak and generally nonsignificant trend toward larger particle size at higher dilution ratios.

LangmuirVol. 41(42)
Lund University (SE), Doho University (JP), Centre for Biomedical Engineering and Physics (SE), International Iberian Nanotechnology Laboratory (PT), Centre for Environment Education (IN), Swiss Federal Laboratories for Materials Science and Technology (CH), University of Minho (PT)
Openalex Percentile: Top 71%
Innovative Microfluidic and Catalytic Techniques Innovation
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.