Biomechanical Evaluation of Interosseous-to-Interosseous Wiring Technique (IIWT) and Interosseous-to-Interdental Wiring Technique (IIDWT) to Repair Simulated Transverse Feline Caudal Mandibular Fractures

Mandibular fractures in cats are relatively common and likely to cause malocclusion. Maxillomandibular fixation and internal fixation with plates and screws are among the described repair methods in the literature. Interosseous wiring and interdental splints are surgical techniques indicated for simple and stable fractures. The purpose of this study was to compare the mechanical stability of 2 caudal mandibular transverse fracture repair techniques using interosseous wires and acrylic interdental splints. Technique 1-Interosseous-to-Interosseous Wire Technique (IIWT) involved fracture stabilization using 2 interosseous wires between the bone fragments on the dorsal and ventral aspects of the mandible. Technique 2-Interosseous-to-Interdental Wire Technique (IIDWT) involved utilization of one interosseous wire between the 2 bone fragments on the ventral aspect of the mandible and a modified interdental wire pattern and splint, made of bis-acrylic material, on the alveolar margin of the mandible. Twenty feline mandibles with grossly normal tooth morphology and complete dentition were chosen for the study. There was no statistical difference between the mechanical strength of IIWT and IIDWT. The peak loads were determined to be 58.47N for IIWT and 63.98N for IIDWT. These findings suggest that IIWT provides mechanical stability comparable to IIDWT and may serve as a simpler alternative for mandibular fracture fixation that allows the patient to return to normal function more quickly. More clinical studies need to be performed to better assess overall stability of repairs in a clinical patient and to determine accurate bite forces in cats.

Authors

Institutions

Publication Details

Journal
Journal of Veterinary Dentistry
Published
2025-10-17
DOI
https://doi.org/10.1177/08987564251384715
Primary Topic
Orthopedic Surgery and Rehabilitation
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Biomechanical Evaluation of Interosseous-to-Interosseous Wiring Technique (IIWT) and Interosseous-to-Interdental Wiring Technique (IIDWT) to Repair Simulated Transverse Feline Caudal Mandibular Fractures

Elahe Ganji, Katherine Kling, Sandra Manfra Marretta, S Rao
Journal of Veterinary Dentistry
Orthopedic Surgery and Rehabilitation
article

Biomechanical Evaluation of Interosseous-to-Interosseous Wiring Technique (IIWT) and Interosseous-to-Interdental Wiring Technique (IIDWT) to Repair Simulated Transverse Feline Caudal Mandibular Fractures

Elahe Ganji, Katherine Kling, Sandra Manfra Marretta, S Rao
article en

Abstract

Mandibular fractures in cats are relatively common and likely to cause malocclusion. Maxillomandibular fixation and internal fixation with plates and screws are among the described repair methods in the literature. Interosseous wiring and interdental splints are surgical techniques indicated for simple and stable fractures. The purpose of this study was to compare the mechanical stability of 2 caudal mandibular transverse fracture repair techniques using interosseous wires and acrylic interdental splints. Technique 1-Interosseous-to-Interosseous Wire Technique (IIWT) involved fracture stabilization using 2 interosseous wires between the bone fragments on the dorsal and ventral aspects of the mandible. Technique 2-Interosseous-to-Interdental Wire Technique (IIDWT) involved utilization of one interosseous wire between the 2 bone fragments on the ventral aspect of the mandible and a modified interdental wire pattern and splint, made of bis-acrylic material, on the alveolar margin of the mandible. Twenty feline mandibles with grossly normal tooth morphology and complete dentition were chosen for the study. There was no statistical difference between the mechanical strength of IIWT and IIDWT. The peak loads were determined to be 58.47N for IIWT and 63.98N for IIDWT. These findings suggest that IIWT provides mechanical stability comparable to IIDWT and may serve as a simpler alternative for mandibular fracture fixation that allows the patient to return to normal function more quickly. More clinical studies need to be performed to better assess overall stability of repairs in a clinical patient and to determine accurate bite forces in cats.

Journal of Veterinary DentistryVol. 43(2)
University of Illinois Urbana-Champaign (US), University of Dental Medicine (MM), University of Illinois System (US)
Openalex Percentile: Top 54%
Orthopedic Surgery and Rehabilitation
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.