Incomplete Absorption Correction Results in an Increased Positive Mean Value of Weighted Residuals

Incomplete absorption correction procedures in single-crystal diffraction experiments leave a characteristic trace—a “fingerprint”—in the residuals. Specifically, weak intensities are systematically overestimated, contributing disproportionately and sometimes even dominantly to the chi-square sum in least squares refinements. An analysis of six published crystal structures spanning a wide range of absorption coefficients reveals a consistent positive shift of the weighted residuals, which were significant for crystals with >5.02 mm−1. This shift is all the stronger the greater the absorption coefficient and is accompanied by a proportionally increasing fraction of positive excess residuals. The simultaneous increase in the mean value of the residuals and the fraction of positive excess residuals proves that the shift is not caused by strong reflections or isolated outliers, but rather by the systematic overestimation of many weak intensities. Diagnostic plots and statistical metrics are presented for additional published data sets, supporting the generality of the findings. These findings can support the development of improved methods for absorption correction, which lead to physically meaningful thermal motion parameters even with strong absorption.

Authors

Institutions

Publication Details

Journal
Crystals
Published
2025-10-16
DOI
https://doi.org/10.3390/cryst15100898
Citations
1
Primary Topic
Fatigue and fracture mechanics
Type
article
Field-Weighted Citation Impact
0.86
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Incomplete Absorption Correction Results in an Increased Positive Mean Value of Weighted Residuals

Julian Henn
1 citations
Crystals
Fatigue and fracture mechanics
0.86
article

Incomplete Absorption Correction Results in an Increased Positive Mean Value of Weighted Residuals

Julian Henn
article en
1 citations

Abstract

Incomplete absorption correction procedures in single-crystal diffraction experiments leave a characteristic trace—a “fingerprint”—in the residuals. Specifically, weak intensities are systematically overestimated, contributing disproportionately and sometimes even dominantly to the chi-square sum in least squares refinements. An analysis of six published crystal structures spanning a wide range of absorption coefficients reveals a consistent positive shift of the weighted residuals, which were significant for crystals with >5.02 mm−1. This shift is all the stronger the greater the absorption coefficient and is accompanied by a proportionally increasing fraction of positive excess residuals. The simultaneous increase in the mean value of the residuals and the fraction of positive excess residuals proves that the shift is not caused by strong reflections or isolated outliers, but rather by the systematic overestimation of many weak intensities. Diagnostic plots and statistical metrics are presented for additional published data sets, supporting the generality of the findings. These findings can support the development of improved methods for absorption correction, which lead to physically meaningful thermal motion parameters even with strong absorption.

CrystalsVol. 15(10)
University of Bayreuth (DE)
Openalex Percentile: Top 24%
Fatigue and fracture mechanics
0.86
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Incomplete Absorption Correction Results in an Increased Positive Mean Value of Weighted Residuals — Julian Henn · Crystals (2025) | TGRS Research Map | TGRS