Ensemble deep learning model for accurate assessment of renal fibrosis in chronic kidney disease using two-dimensional shear wave elastography images

The accuracy of shear wave elastography for non-invasive assessment of renal fibrosis (RF) in chronic kidney disease (CKD) needs further improvement. We developed a tool using an ensemble deep learning model (EDLM) that can accurately assess RF in CKD patients based solely on two-dimensional shear wave elastography (2D-SWE) images. Retrospective data were collected from CKD patients between April 2019 and October 2024, along with renal 2D-SWE images obtained before biopsy. Pathological evaluation was the reference standard of RF. All patients were randomly divided into training, validation, and test sets in a 7:1:2 ratio. An EDLM integrating three convolutional neural networks (ResNet18, DenseNet121, and EfficientNet-b7) through a voting strategy at the output level was developed and validated using 2D-SWE images. The diagnostic performance of the EDLM was compared with that of radiologists. A total of 286 CKD patients (mean age ± standard deviation: 41.86 ± 14.94, males: 162) and 858 2D-SWE images (mild RF: 405, moderate-severe RF: 453) were included. In the test set, EDLM achieved an accuracy of 93.0% (95% CI: 88.1, 95.9), negative predictive value of 89.6% (95% CI: 81.5, 94.5), positive predictive value of 96.4% (95% CI: 90.0, 98.8), specificity of 96.3% (95% CI: 89.7, 98.7), and sensitivity of 90.0% (95% CI: 82.1, 94.7). The area under the receiver operating characteristic curves of the EDLM was 0.989, surpassing experienced radiologist by 0.186 (P < 0.001) and less experienced radiologist by 0.279 (P < 0.001). EDLM based on 2D-SWE images significantly improved the diagnostic performance of RF in CKD. The EDLM was expected to be a potential tool for accurately non-invasive assessment of RF in CKD.

Authors

Institutions

Publication Details

Journal
BMC Medical Imaging
Published
2025-10-17
DOI
https://doi.org/10.1186/s12880-025-01964-y
Primary Topic
Ultrasound and Hyperthermia Applications
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Ensemble deep learning model for accurate assessment of renal fibrosis in chronic kidney disease using two-dimensional shear wave elastography images

Shushan Zhang, Zhongzhen Su, Dalin Ye, Feile Ye et al.
BMC Medical Imaging
Ultrasound and Hyperthermia Applications
article

Ensemble deep learning model for accurate assessment of renal fibrosis in chronic kidney disease using two-dimensional shear wave elastography images

Shushan Zhang, Zhongzhen Su, Dalin Ye, Feile Ye, Yongquan Huang, Tong Li, Jiaxin Chen, Zhaoxing Ou, Shuqing Wang
article en

Abstract

The accuracy of shear wave elastography for non-invasive assessment of renal fibrosis (RF) in chronic kidney disease (CKD) needs further improvement. We developed a tool using an ensemble deep learning model (EDLM) that can accurately assess RF in CKD patients based solely on two-dimensional shear wave elastography (2D-SWE) images. Retrospective data were collected from CKD patients between April 2019 and October 2024, along with renal 2D-SWE images obtained before biopsy. Pathological evaluation was the reference standard of RF. All patients were randomly divided into training, validation, and test sets in a 7:1:2 ratio. An EDLM integrating three convolutional neural networks (ResNet18, DenseNet121, and EfficientNet-b7) through a voting strategy at the output level was developed and validated using 2D-SWE images. The diagnostic performance of the EDLM was compared with that of radiologists. A total of 286 CKD patients (mean age ± standard deviation: 41.86 ± 14.94, males: 162) and 858 2D-SWE images (mild RF: 405, moderate-severe RF: 453) were included. In the test set, EDLM achieved an accuracy of 93.0% (95% CI: 88.1, 95.9), negative predictive value of 89.6% (95% CI: 81.5, 94.5), positive predictive value of 96.4% (95% CI: 90.0, 98.8), specificity of 96.3% (95% CI: 89.7, 98.7), and sensitivity of 90.0% (95% CI: 82.1, 94.7). The area under the receiver operating characteristic curves of the EDLM was 0.989, surpassing experienced radiologist by 0.186 (P < 0.001) and less experienced radiologist by 0.279 (P < 0.001). EDLM based on 2D-SWE images significantly improved the diagnostic performance of RF in CKD. The EDLM was expected to be a potential tool for accurately non-invasive assessment of RF in CKD.

BMC Medical ImagingVol. 25(1)
Sun Yat-sen University (CN), Fifth Affiliated Hospital of Sun Yat-sen University (CN)
Sun Yat-sen University
Openalex Percentile: Top 71%
Ultrasound and Hyperthermia Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.