Fabrication and characterization of three-dimensional nerve conduits containing cobalt oxide/nickel oxide nanoparticles integrated with bergamot oil

Peripheral nerve injuries (PNIs) represent a significant clinical challenge worldwide, leading to severe sensory and motor dysfunction and negatively impacting patients' quality of life. Autologous nerve grafts remain the current gold standard for bridging peripheral nerve gaps; however, their use is limited by donor-site morbidity, such as sensory loss and scarring, as well as technical difficulties and prolonged surgical procedures. To overcome these limitations, tissue-engineered nerve conduits have emerged as promising alternatives. In this study, three-dimensional (3D) nerve conduits were fabricated <i>via</i> co-electrospinning of polycaprolactone (PCL) and polyethylene glycol (PEG) polymers, with the incorporation of bergamot oil (BEO) and cobalt oxide (CoO) and nickel oxide (Ni<sub>2</sub>O<sub>3</sub>) nanoparticles to enhance nerve regeneration. The conduits exhibited cumulative release rates of 0.44 ± 0.005% for CoO, 0.26 ± 0.004% for Ni<sub>2</sub>O<sub>3</sub>, and 0.017 ± 0.005% for BEO. Mechanical testing revealed a Young's modulus of 16.81-17.94 MPa, indicating a durable yet flexible structure. Electrical conductivity improved markedly from 5.6 × 10<sup>-9</sup> S/cm to 2-2.2 × 10<sup>-7</sup> S/cm. Furthermore, <i>in vitro</i> studies with C6 neuroglial cells demonstrated cell viability ranging between 67-155 ± 4.87%, confirming the biocompatibility of the scaffolds. To the best of our knowledge, this is the first report on the incorporation of BEO into PEG/PCL-based 3D nerve conduits. The resulting scaffolds exhibited favorable mechanical strength, flexibility, electrical conductivity, and cytocompatibility, highlighting their potential as promising candidates for peripheral nerve regeneration.

Authors

Institutions

Publication Details

Journal
Journal of Biomaterials Science Polymer Edition
Published
2025-10-16
DOI
https://doi.org/10.1080/09205063.2025.2573138
Primary Topic
Neuroscience and Neural Engineering
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Fabrication and characterization of three-dimensional nerve conduits containing cobalt oxide/nickel oxide nanoparticles integrated with bergamot oil

Özlem Eğri, Mustafa Caner Karaaslan
Journal of Biomaterials Science Polymer Edition
Neuroscience and Neural Engineering
article

Fabrication and characterization of three-dimensional nerve conduits containing cobalt oxide/nickel oxide nanoparticles integrated with bergamot oil

Özlem Eğri, Mustafa Caner Karaaslan
article en

Abstract

Peripheral nerve injuries (PNIs) represent a significant clinical challenge worldwide, leading to severe sensory and motor dysfunction and negatively impacting patients' quality of life. Autologous nerve grafts remain the current gold standard for bridging peripheral nerve gaps; however, their use is limited by donor-site morbidity, such as sensory loss and scarring, as well as technical difficulties and prolonged surgical procedures. To overcome these limitations, tissue-engineered nerve conduits have emerged as promising alternatives. In this study, three-dimensional (3D) nerve conduits were fabricated <i>via</i> co-electrospinning of polycaprolactone (PCL) and polyethylene glycol (PEG) polymers, with the incorporation of bergamot oil (BEO) and cobalt oxide (CoO) and nickel oxide (Ni<sub>2</sub>O<sub>3</sub>) nanoparticles to enhance nerve regeneration. The conduits exhibited cumulative release rates of 0.44 ± 0.005% for CoO, 0.26 ± 0.004% for Ni<sub>2</sub>O<sub>3</sub>, and 0.017 ± 0.005% for BEO. Mechanical testing revealed a Young's modulus of 16.81-17.94 MPa, indicating a durable yet flexible structure. Electrical conductivity improved markedly from 5.6 × 10<sup>-9</sup> S/cm to 2-2.2 × 10<sup>-7</sup> S/cm. Furthermore, <i>in vitro</i> studies with C6 neuroglial cells demonstrated cell viability ranging between 67-155 ± 4.87%, confirming the biocompatibility of the scaffolds. To the best of our knowledge, this is the first report on the incorporation of BEO into PEG/PCL-based 3D nerve conduits. The resulting scaffolds exhibited favorable mechanical strength, flexibility, electrical conductivity, and cytocompatibility, highlighting their potential as promising candidates for peripheral nerve regeneration.

Journal of Biomaterials Science Polymer Edition
Tokat Gaziosmanpaşa Üniversitesi (TR)
Openalex Percentile: Top 68%
Neuroscience and Neural Engineering
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Fabrication and characterization of three-dimensional nerve conduits containing cobalt oxide/nickel oxide nanoparticles integrated with bergamot oil — Özlem Eğri, Mustafa Caner Karaaslan · Journal of Biomaterials Science Polymer Edition (2025) | TGRS Research Map | TGRS