The Impact of Centrifugation Devices and Collection Tubes on Fibrin Characteristics and Growth Factor Release Under High- and Low-Speed Protocols

<b>Background:</b> Platelet-rich fibrin (PRF) is an autologous platelet concentrate (APC) produced through blood centrifugation. Despite the development of various centrifugation systems, protocol variability continues to pose challenges in selecting the optimal method. This study investigated the effects of three different centrifuges and collection tubes on the fibrin characteristics and growth factor release in leukocyte- and platelet-rich fibrin (L-PRF) and advanced platelet-rich fibrin plus (A-PRF+). <b>Methods</b>: Blood samples from six healthy female volunteers were processed using three centrifuges (Duo, IntraSpin, and LMC-3000) and three collection tubes (Pyrex, A-P, and silica-coated plastic) under high- (~700× <i>g</i> for 12 min) and low-speed (~200× <i>g</i> for 8 min) protocols. Fibrin clot weight and length were assessed. Growth factor release of platelet-derived growth factor-BB (PDGF-BB) and vascular endothelial growth factor (VEGF) was quantified using ELISA. Fibrin architecture was examined via scanning electron microscopy (SEM). <b>Results</b>: High-speed protocols tended to produce larger clots, whereas low-speed protocols generated smaller but more biologically active matrices. The IntraSpin and Duo centrifuges yielded greater clot dimensions and higher growth factor release than the LMC-3000. While tube type had no significant effect on growth factor levels, silica-coated tubes tended to produce the largest clots. The Pyrex tubes demonstrated comparable or superior growth factor release. <b>Conclusions</b>: PRF quality is influenced by centrifuge design, g-force, and tube material. Low-speed protocols with certified centrifuges are recommended, and FDA-approved glass tubes may provide a reliable alternative to reduce silica-related risks. Standardization and appropriate material selection are essential for consistent, safe, and effective regenerative outcomes.

Authors

Institutions

Publication Details

Journal
Dentistry Journal
Published
2025-10-17
DOI
https://doi.org/10.3390/dj13100476
Citations
3
Primary Topic
Periodontal Regeneration and Treatments
Type
article
Field-Weighted Citation Impact
5.51

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

The Impact of Centrifugation Devices and Collection Tubes on Fibrin Characteristics and Growth Factor Release Under High- and Low-Speed Protocols

Wutigri Nimlamool, Supatra Sang-in, Oranit Bunyatratchata
3 citations
Dentistry Journal
Periodontal Regeneration and Treatments
5.51
article

The Impact of Centrifugation Devices and Collection Tubes on Fibrin Characteristics and Growth Factor Release Under High- and Low-Speed Protocols

Wutigri Nimlamool, Supatra Sang-in, Oranit Bunyatratchata
article en
3 citations

Abstract

<b>Background:</b> Platelet-rich fibrin (PRF) is an autologous platelet concentrate (APC) produced through blood centrifugation. Despite the development of various centrifugation systems, protocol variability continues to pose challenges in selecting the optimal method. This study investigated the effects of three different centrifuges and collection tubes on the fibrin characteristics and growth factor release in leukocyte- and platelet-rich fibrin (L-PRF) and advanced platelet-rich fibrin plus (A-PRF+). <b>Methods</b>: Blood samples from six healthy female volunteers were processed using three centrifuges (Duo, IntraSpin, and LMC-3000) and three collection tubes (Pyrex, A-P, and silica-coated plastic) under high- (~700× <i>g</i> for 12 min) and low-speed (~200× <i>g</i> for 8 min) protocols. Fibrin clot weight and length were assessed. Growth factor release of platelet-derived growth factor-BB (PDGF-BB) and vascular endothelial growth factor (VEGF) was quantified using ELISA. Fibrin architecture was examined via scanning electron microscopy (SEM). <b>Results</b>: High-speed protocols tended to produce larger clots, whereas low-speed protocols generated smaller but more biologically active matrices. The IntraSpin and Duo centrifuges yielded greater clot dimensions and higher growth factor release than the LMC-3000. While tube type had no significant effect on growth factor levels, silica-coated tubes tended to produce the largest clots. The Pyrex tubes demonstrated comparable or superior growth factor release. <b>Conclusions</b>: PRF quality is influenced by centrifuge design, g-force, and tube material. Low-speed protocols with certified centrifuges are recommended, and FDA-approved glass tubes may provide a reliable alternative to reduce silica-related risks. Standardization and appropriate material selection are essential for consistent, safe, and effective regenerative outcomes.

Dentistry JournalVol. 13(10)
Chiang Mai University (TH)
Chiang Mai University
Openalex Percentile: Top 4%
Periodontal Regeneration and Treatments
5.51
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

The Impact of Centrifugation Devices and Collection Tubes on Fibrin Characteristics and Growth Factor Release Under High- and Low-Speed Protocols — Wutigri Nimlamool, Supatra Sang-in, et al. · Dentistry Journal (2025) | TGRS Research Map | TGRS