Validating the performance of low-cost IAQ sensors through co-location

Low-cost indoor air quality (IAQ) sensors offer new opportunities for real-time monitoring in the built environment by occupants and researchers. However, their performance can vary substantially depending on the environmental conditions. This study presents a comprehensive evaluation of carbon dioxide (CO 2 ) and fine particulate matter (PM 2.5 ) measurements from two consumer-grade low-cost sensors (the Airthings View Plus for CO 2 only and Air Gradient Pro for CO 2 and PM 2.5 ) through co-location tests with two reference instruments, Graywolf DSII-8 for CO 2 and Lighthouse Handheld 3016 for PM 2.5 . Using time-series analysis, linear regression, Pearson correlation, Root-Mean Squared Error (RMSE), Bland-Altman test, and paired t -tests, we assess the precision and accuracy of these sensors. At a 5-minute sampling interval, the Air Gradient sensor had a higher coefficient of determination ( R 2 ), stronger Pearson correlation, and narrower range of limits of agreement (LoAs), but higher bias (i.e. the mean difference) and RMSE, suggesting higher precision but lower accuracy when compared to Airthings. As a result, it can perform well for tracking the relative changes in CO 2 , though less ideal for absolute concentrations without calibration. For PM 2.5 , the Air Gradient also had relatively high R 2 (0.79), moderately strong Pearson correlation (ρ = 0.69, p < 0.05), and a narrow range of LOAs (30.1 μg/m 3 ) and low RMSE (5.8 μg/m 3 ). Averaging the 5-minute measurements over 30-minute intervals generally improved the accuracy and precision of both sensors. However, statistically significant differences from the reference instruments remained for both sensors. Overall, this study offers a multi-metric assessment of consumer-grade sensors and highlights the need for in-situ calibration prior to long-term deployment.

Authors

Institutions

Publication Details

Journal
Journal of Building Physics
Published
2025-10-17
DOI
https://doi.org/10.1177/17442591251367436
Primary Topic
Air Quality Monitoring and Forecasting
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Validating the performance of low-cost IAQ sensors through co-location

Helen Stopps, N. H. S. Zaky, Tianyuan Li
Journal of Building Physics
Air Quality Monitoring and Forecasting
article

Validating the performance of low-cost IAQ sensors through co-location

Helen Stopps, N. H. S. Zaky, Tianyuan Li
article en

Abstract

Low-cost indoor air quality (IAQ) sensors offer new opportunities for real-time monitoring in the built environment by occupants and researchers. However, their performance can vary substantially depending on the environmental conditions. This study presents a comprehensive evaluation of carbon dioxide (CO 2 ) and fine particulate matter (PM 2.5 ) measurements from two consumer-grade low-cost sensors (the Airthings View Plus for CO 2 only and Air Gradient Pro for CO 2 and PM 2.5 ) through co-location tests with two reference instruments, Graywolf DSII-8 for CO 2 and Lighthouse Handheld 3016 for PM 2.5 . Using time-series analysis, linear regression, Pearson correlation, Root-Mean Squared Error (RMSE), Bland-Altman test, and paired t -tests, we assess the precision and accuracy of these sensors. At a 5-minute sampling interval, the Air Gradient sensor had a higher coefficient of determination ( R 2 ), stronger Pearson correlation, and narrower range of limits of agreement (LoAs), but higher bias (i.e. the mean difference) and RMSE, suggesting higher precision but lower accuracy when compared to Airthings. As a result, it can perform well for tracking the relative changes in CO 2 , though less ideal for absolute concentrations without calibration. For PM 2.5 , the Air Gradient also had relatively high R 2 (0.79), moderately strong Pearson correlation (ρ = 0.69, p < 0.05), and a narrow range of LOAs (30.1 μg/m 3 ) and low RMSE (5.8 μg/m 3 ). Averaging the 5-minute measurements over 30-minute intervals generally improved the accuracy and precision of both sensors. However, statistically significant differences from the reference instruments remained for both sensors. Overall, this study offers a multi-metric assessment of consumer-grade sensors and highlights the need for in-situ calibration prior to long-term deployment.

Journal of Building Physics
University of Waterloo (CA), Toronto Metropolitan University (CA)
Openalex Percentile: Top 73%
Air Quality Monitoring and Forecasting
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Validating the performance of low-cost IAQ sensors through co-location — Helen Stopps, N. H. S. Zaky, et al. · Journal of Building Physics (2025) | TGRS Research Map | TGRS