Design of a Heat Pump Cycle for PCA systems and Analysis of CO₂ Emission for Aircraft Heating on the Ground

This study proposes a heat pump-based Pre-Conditioned Air (PCA) system as an alternative to the Auxiliary Power Unit (APU), which emits a significant amount of CO₂ during aircraft ground operations. We designed a series of four single-stage compression heat pump modules and evaluated various HydroFluoroOlefin (HFO) refrigerants. R1234ze(E) was selected as the most suitable refrigerant based on both the Coefficient of Performance (COP) and the maximum pressure ratio of the system. Additionally, we analyzed the performance of the designed heat pump cycle using 10 years of weather data from Incheon International Airport. As a result, we confirmed that the designed heat pump system could reduce CO₂ emissions by up to 62% compared to the conventional APU system, demonstrating the technical and environmental feasibility of the PCA heat pump system.

Authors

Publication Details

Journal
Korean Journal of Air-Conditioning and Refrigeration Engineering
Published
2025-10-17
DOI
https://doi.org/10.6110/kjacr.2025.37.10.480
Primary Topic
Refrigeration and Air Conditioning Technologies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Design of a Heat Pump Cycle for PCA systems and Analysis of CO₂ Emission for Aircraft Heating on the Ground

Jin‐Man Kim
Korean Journal of Air-Conditioning and Refrigeration Engineering
Refrigeration and Air Conditioning Technologies
article

Design of a Heat Pump Cycle for PCA systems and Analysis of CO₂ Emission for Aircraft Heating on the Ground

Jin‐Man Kim
article en

Abstract

This study proposes a heat pump-based Pre-Conditioned Air (PCA) system as an alternative to the Auxiliary Power Unit (APU), which emits a significant amount of CO₂ during aircraft ground operations. We designed a series of four single-stage compression heat pump modules and evaluated various HydroFluoroOlefin (HFO) refrigerants. R1234ze(E) was selected as the most suitable refrigerant based on both the Coefficient of Performance (COP) and the maximum pressure ratio of the system. Additionally, we analyzed the performance of the designed heat pump cycle using 10 years of weather data from Incheon International Airport. As a result, we confirmed that the designed heat pump system could reduce CO₂ emissions by up to 62% compared to the conventional APU system, demonstrating the technical and environmental feasibility of the PCA heat pump system.

Korean Journal of Air-Conditioning and Refrigeration EngineeringVol. 37(10)
Openalex Percentile: Top 69%
Refrigeration and Air Conditioning Technologies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.