Small-Scale Experimental Study on Smoke Blocking and Thermal Insulation Performance of Water Mist Sprinkler

To investigate the performance patterns of high-pressure water mist sprinklers with different flow coefficients in smoke containment and thermal insulation during fire suppression, this study conducted droplet size experiments and small-scale fire tests at 8 MPa pressure using six sprinkler types with flow coefficients (K) of 0.5, 0.7, 1.0, 1.2, 1.5, and 2.0. These findings were systematically analyzed in conjunction with FDS numerical simulations. Droplet size results indicate optimal atomization for K = 1.0, 1.2, and 1.5 sprinklers, producing fine droplets with concentrated distribution. Small-scale experiments and simulations further compared their smoke suppression and heat insulation performance. Findings show K = 1.5 delivers superior smoke suppression and cooling effects, reducing protected area temperatures by 20~45 °C compared to other conditions while minimizing smoke spread. Although visibility was slightly lower than at K = 1.2 due to droplet size and particle count, the overall performance was superior. This study conclusively identified K = 1.5 as the optimal flow parameter, providing experimental evidence and theoretical support for the engineering application of high-pressure water mist sprinklers.

Authors

Institutions

Publication Details

Journal
Fire
Published
2025-10-16
DOI
https://doi.org/10.3390/fire8100401
Primary Topic
Fire dynamics and safety research
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Small-Scale Experimental Study on Smoke Blocking and Thermal Insulation Performance of Water Mist Sprinkler

Xiaopo Wang, Qiang Liang, Jiangjiang Lv, Hui Xu et al.
Fire
Fire dynamics and safety research
article

Small-Scale Experimental Study on Smoke Blocking and Thermal Insulation Performance of Water Mist Sprinkler

Xiaopo Wang, Qiang Liang, Jiangjiang Lv, Hui Xu, Zhenyu Liu, Jianan Men
article en

Abstract

To investigate the performance patterns of high-pressure water mist sprinklers with different flow coefficients in smoke containment and thermal insulation during fire suppression, this study conducted droplet size experiments and small-scale fire tests at 8 MPa pressure using six sprinkler types with flow coefficients (K) of 0.5, 0.7, 1.0, 1.2, 1.5, and 2.0. These findings were systematically analyzed in conjunction with FDS numerical simulations. Droplet size results indicate optimal atomization for K = 1.0, 1.2, and 1.5 sprinklers, producing fine droplets with concentrated distribution. Small-scale experiments and simulations further compared their smoke suppression and heat insulation performance. Findings show K = 1.5 delivers superior smoke suppression and cooling effects, reducing protected area temperatures by 20~45 °C compared to other conditions while minimizing smoke spread. Although visibility was slightly lower than at K = 1.2 due to droplet size and particle count, the overall performance was superior. This study conclusively identified K = 1.5 as the optimal flow parameter, providing experimental evidence and theoretical support for the engineering application of high-pressure water mist sprinklers.

FireVol. 8(10)
China People's Police University (CN), Xi'an Jiaotong University (CN)
Openalex Percentile: Top 64%
Fire dynamics and safety research
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.