Revisiting the impulse response creates an improved PID autotuner

Industrial practice navigates a robust controller tuning due to fairly uncertain process information. A comprehensive process identification is often avoided due to operating conditions, continuous manufacturing, etc. When process properties or operating conditions change, controller re-tuning is often ignored resulting in long-term lower productivity outcomes. We introduce a novel methodology to extract relevant process information from short and minimally rich datasets. Specifically, a sine test of duration related to settling time of the loop is superimposed on nominal process inputs. The method can be applied under both open and closed-loop operating conditions. The process impulse response coefficients are estimated and consequently provides a band limited, but accurate, frequency response. Based on this information, a robust PID controller can be (automatically) tuned. Numerical examples are provided to validate the theory. Additional experimental validation on an integrating and nonminimum phase process and on a poorly damped system is also provided. A comparison with one of the most widely used autotuning methods illustrates the relevance of the proposed approach.

Authors

Institutions

Publication Details

Journal
Scientific Reports
Published
2025-10-16
DOI
https://doi.org/10.1038/s41598-025-20027-4
Primary Topic
Advanced Control Systems Design
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Revisiting the impulse response creates an improved PID autotuner

Clara M. Ionescu, Isabela Birs, Cristina I. Mureşan, Robin De Keyser
Scientific Reports
Advanced Control Systems Design
article

Revisiting the impulse response creates an improved PID autotuner

Clara M. Ionescu, Isabela Birs, Cristina I. Mureşan, Robin De Keyser
article en

Abstract

Industrial practice navigates a robust controller tuning due to fairly uncertain process information. A comprehensive process identification is often avoided due to operating conditions, continuous manufacturing, etc. When process properties or operating conditions change, controller re-tuning is often ignored resulting in long-term lower productivity outcomes. We introduce a novel methodology to extract relevant process information from short and minimally rich datasets. Specifically, a sine test of duration related to settling time of the loop is superimposed on nominal process inputs. The method can be applied under both open and closed-loop operating conditions. The process impulse response coefficients are estimated and consequently provides a band limited, but accurate, frequency response. Based on this information, a robust PID controller can be (automatically) tuned. Numerical examples are provided to validate the theory. Additional experimental validation on an integrating and nonminimum phase process and on a poorly damped system is also provided. A comparison with one of the most widely used autotuning methods illustrates the relevance of the proposed approach.

Scientific ReportsVol. 15(1)
Technical University of Cluj-Napoca (RO), Flanders Make (Belgium) (BE)
Ministerul Cercetării, Inovării şi Digitalizării, Unitatea Executiva pentru Finantarea Invatamantului Superior, a Cercetarii, Dezvoltarii si Inovarii, Vlaamse regering
Openalex Percentile: Top 62%
Advanced Control Systems Design
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.