Noninvasive Blood Glucose Monitoring via Vein Visualization-Guided Confocal Raman Spectroscopy and Heterogeneous Ensemble Learning

Raman spectroscopy holds promise for noninvasive glucose monitoring. But its practical implementation is constrained by challenges like imprecise sampling locations, poorly resolved glucose-specific features, and small data sets. To overcome these limitations, venous visualization technology (VVT) is, for the first time, integrated with a confocal Raman spectroscopy (CRS) system to improve spectral sampling precision and quality. Moreover, a stacking ensemble learning framework combining multiple heterogeneous base models is proposed to improve model generalization while mitigating overfitting for accurate glucose prediction. Meanwhile, an internal standard method, combined with the Raman spectrum intelligent augmentation engine and a feature selection-driven stacking model, is employed to expand the effective data set size and optimize model weight allocation. For method validation, regression analysis is conducted on synthetic blood samples and in vivo venous blood glucose, with classification of samples based on varying glucose levels. Results indicate that, for in vitro synthetic blood experiment, the glucose peak area ratio is significantly linearly correlated with concentration, with the regression R2 value reaching 0.9897. For the in vivo transcutaneous test, VVT enhances the accuracy of venous localization by approximately 20%, with the regression R2 between the predicted and reference values reaching 0.928. In the classification experiment, reliable results are obtained for synthetic blood using 2 mmol/L intervals during training; when transitioned to the in vivo transdermal test, transfer learning boosts the accuracy by 2 percentage points to 92% for distinguishing between pre- and postprandial glucose states. These results establish a foundation for the application of AI-based noninvasive glucose monitoring technology.

Authors

Institutions

Publication Details

Journal
ACS Photonics
Published
2025-10-16
DOI
https://doi.org/10.1021/acsphotonics.5c01694
Primary Topic
Spectroscopy Techniques in Biomedical and Chemical Research
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Noninvasive Blood Glucose Monitoring via Vein Visualization-Guided Confocal Raman Spectroscopy and Heterogeneous Ensemble Learning

Yuqing Du, Xiaopeng Wang, Qiang Yang, Z. P. Wang et al.
ACS Photonics
Spectroscopy Techniques in Biomedical and Chemical Research
article

Noninvasive Blood Glucose Monitoring via Vein Visualization-Guided Confocal Raman Spectroscopy and Heterogeneous Ensemble Learning

Yuqing Du, Xiaopeng Wang, Qiang Yang, Z. P. Wang, Mingyuan Liu, Ming Yang, Haibing Lv, Y. Qi, Qiang Liu
article en

Abstract

Raman spectroscopy holds promise for noninvasive glucose monitoring. But its practical implementation is constrained by challenges like imprecise sampling locations, poorly resolved glucose-specific features, and small data sets. To overcome these limitations, venous visualization technology (VVT) is, for the first time, integrated with a confocal Raman spectroscopy (CRS) system to improve spectral sampling precision and quality. Moreover, a stacking ensemble learning framework combining multiple heterogeneous base models is proposed to improve model generalization while mitigating overfitting for accurate glucose prediction. Meanwhile, an internal standard method, combined with the Raman spectrum intelligent augmentation engine and a feature selection-driven stacking model, is employed to expand the effective data set size and optimize model weight allocation. For method validation, regression analysis is conducted on synthetic blood samples and in vivo venous blood glucose, with classification of samples based on varying glucose levels. Results indicate that, for in vitro synthetic blood experiment, the glucose peak area ratio is significantly linearly correlated with concentration, with the regression R2 value reaching 0.9897. For the in vivo transcutaneous test, VVT enhances the accuracy of venous localization by approximately 20%, with the regression R2 between the predicted and reference values reaching 0.928. In the classification experiment, reliable results are obtained for synthetic blood using 2 mmol/L intervals during training; when transitioned to the in vivo transdermal test, transfer learning boosts the accuracy by 2 percentage points to 92% for distinguishing between pre- and postprandial glucose states. These results establish a foundation for the application of AI-based noninvasive glucose monitoring technology.

ACS PhotonicsVol. 12(11)
Beijing Institute of Petrochemical Technology (CN), Capital University (US), Capital Medical University (CN), China-Japan Friendship Hospital (CN), Beijing Academy of Artificial Intelligence (CN), Beijing Friendship Hospital (CN)
Openalex Percentile: Top 79%
Spectroscopy Techniques in Biomedical and Chemical Research
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.