Inter-institutional variability in CT-to-mass-density conversion tables for helical tomotherapy: a national survey in Japan

This study evaluates current practices and challenges associated with computed tomography number-to-mass density (CT-MD) conversion tables in helical tomotherapy across Japan and explores directions for standardization and quality improvement amid the increasing adoption of adaptive radiotherapy (ART). A nationwide web-based survey was conducted across 34 institutions utilizing the Radixact system. Data were collected on CT acquisition protocols, calibration phantoms, density plugs, reconstruction algorithms, table registration timing and quality assurance (QA) frequency. Registered CT-MD tables were categorized by CT modality: Simulation CT (SimCT), ClearRT and CTrue. ClearRT tables were analyzed by phantom setup (full vs half), and CTrue tables by reconstruction method [filtered back projection (FPB) vs iterative reconstruction (IR)]. Inter-institutional variations in CT numbers and the number of data points were assessed. SimCT tables exhibited the widest variation in the number of data points (median = 10) and high-density CT numbers. ClearRT tables (median = 8) showed variations of up to 300 Hounsfield units (HU) in cortical bone; the half-phantom setup reduced inter-institutional variability. CTrue tables (median = 8) demonstrated high consistency, with negligible differences between IR and FPB. All plug CT numbers of CTrue remained within the tolerance defined by the American Association of Physicists in Medicine Task Group 148. However, CT numbers for air plugs varied by ~±30 HU, indicating inconsistent handling of air reference values. Additionally, 43% of institutions did not perform routine QA. Standardizing phantom geometry, air CT number handling and QA protocols-particularly using half-phantom calibration-may improve CT-MD table consistency and dose accuracy in ART.

Authors

Institutions

Publication Details

Journal
Journal of Radiation Research
Published
2025-09-15
DOI
https://doi.org/10.1093/jrr/rraf063
Primary Topic
Advanced Radiotherapy Techniques
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Inter-institutional variability in CT-to-mass-density conversion tables for helical tomotherapy: a national survey in Japan

Hidetoshi Shimizu, Hiroshi Fukuma, Yasuo Shiota, Takashi Hashido et al.
Journal of Radiation Research
Advanced Radiotherapy Techniques
article

Inter-institutional variability in CT-to-mass-density conversion tables for helical tomotherapy: a national survey in Japan

Hidetoshi Shimizu, Hiroshi Fukuma, Yasuo Shiota, Takashi Hashido, Iori Sumida, Shuichi Ozawa, Yuto Kitagawa, Satoshi Kito, Ryosei Nakada, Keiki Sugi, Shogo Tsunemine, Takehiro Shiinoki, Masumi Numano, Hideyuki Harada
article en

Abstract

This study evaluates current practices and challenges associated with computed tomography number-to-mass density (CT-MD) conversion tables in helical tomotherapy across Japan and explores directions for standardization and quality improvement amid the increasing adoption of adaptive radiotherapy (ART). A nationwide web-based survey was conducted across 34 institutions utilizing the Radixact system. Data were collected on CT acquisition protocols, calibration phantoms, density plugs, reconstruction algorithms, table registration timing and quality assurance (QA) frequency. Registered CT-MD tables were categorized by CT modality: Simulation CT (SimCT), ClearRT and CTrue. ClearRT tables were analyzed by phantom setup (full vs half), and CTrue tables by reconstruction method [filtered back projection (FPB) vs iterative reconstruction (IR)]. Inter-institutional variations in CT numbers and the number of data points were assessed. SimCT tables exhibited the widest variation in the number of data points (median = 10) and high-density CT numbers. ClearRT tables (median = 8) showed variations of up to 300 Hounsfield units (HU) in cortical bone; the half-phantom setup reduced inter-institutional variability. CTrue tables (median = 8) demonstrated high consistency, with negligible differences between IR and FPB. All plug CT numbers of CTrue remained within the tolerance defined by the American Association of Physicists in Medicine Task Group 148. However, CT numbers for air plugs varied by ~±30 HU, indicating inconsistent handling of air reference values. Additionally, 43% of institutions did not perform routine QA. Standardizing phantom geometry, air CT number handling and QA protocols-particularly using half-phantom calibration-may improve CT-MD table consistency and dose accuracy in ART.

Journal of Radiation ResearchVol. 66(6)
Mitsubishi Research Institute (Japan) (JP), Development Bank of Japan (JP), Yamaguchi University (JP), Tokyo Metropolitan Komagome Hospital (JP), Nagoya City University (JP), Shizuoka Cancer Center (JP), Iwata City Hospital (JP), Fujita Health University Hospital (JP), Hiroshima Prefectural Rehabilitation Center (JP), Futaba (Japan) (JP), The University of Osaka (JP)
Accuray
Openalex Percentile: Top 61%
Advanced Radiotherapy Techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.