A Study of a Noncontact Identification Method of Debonding Damage in External Thermal Insulation Composite Systems Based on Nonlinear Vibration

Due to the influence of materials, construction quality, environmental conditions, and artificial factors, debonding damage in external thermal insulation composite systems (ETICS) has become a common issue in the construction field. A reliable and efficient method for identifying the debonding is still lacking. In this study, four groups of external insulation specimens with different degrees of debonding were fabricated. A non-contact detection method based on nonlinear vibration characteristics was employed, using a laser Doppler vibrometer to acquire the vibration response signals of the specimens. The results demonstrate that this technique can effectively distinguish specimens with different levels of debonding and accurately identify and locate the damage. Moreover, the relative position of the signal acquisition point with respect to the debonding area has no significant impact on the detection results.

Authors

Institutions

Publication Details

Journal
Buildings
Published
2025-10-16
DOI
https://doi.org/10.3390/buildings15203728
Citations
1
Primary Topic
Structural Health Monitoring Techniques
Type
article
Field-Weighted Citation Impact
0.95
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A Study of a Noncontact Identification Method of Debonding Damage in External Thermal Insulation Composite Systems Based on Nonlinear Vibration

Yanwen Shi, Xuejun Hou, Bin Yao, Chao Gao et al.
1 citations
Buildings
Structural Health Monitoring Techniques
0.95
article

A Study of a Noncontact Identification Method of Debonding Damage in External Thermal Insulation Composite Systems Based on Nonlinear Vibration

Yanwen Shi, Xuejun Hou, Bin Yao, Chao Gao, Hui Zhou
article en
1 citations

Abstract

Due to the influence of materials, construction quality, environmental conditions, and artificial factors, debonding damage in external thermal insulation composite systems (ETICS) has become a common issue in the construction field. A reliable and efficient method for identifying the debonding is still lacking. In this study, four groups of external insulation specimens with different degrees of debonding were fabricated. A non-contact detection method based on nonlinear vibration characteristics was employed, using a laser Doppler vibrometer to acquire the vibration response signals of the specimens. The results demonstrate that this technique can effectively distinguish specimens with different levels of debonding and accurately identify and locate the damage. Moreover, the relative position of the signal acquisition point with respect to the debonding area has no significant impact on the detection results.

BuildingsVol. 15(20)
Shanghai Harbour Engineering Design & Research Institute (CN)
Openalex Percentile: Top 20%
Structural Health Monitoring Techniques
0.95
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.