Plate Breakage After Mandibular Condylar Fracture Osteosynthesis

Despite the significant ongoing development of fixation materials, plate breakages still occur after osteosynthesis of the mandibular condyles. The aim of this study is to demonstrate the complications caused by fixation material breakages in the hope of inspiring the development of new, more durable plates; we analyzed a total of 238 plates used for osteosynthesis in this anatomical region. Cases where compression screws were used as the sole fixation material were excluded. Plate breakage was found in six cases, which accounted for 2.52% of treated individuals. It seems that most plate breakages can be avoided by maintaining effective patient supervision for up to 6 months after surgery. Risk factors for breakage are identified and guidelines for improving the design of future plates are provided. By analyzing some plate design features, we provide some indications for improving their strength and improving their designs for use in this field.

Authors

Institutions

Publication Details

Journal
Journal of Functional Biomaterials
Published
2025-10-16
DOI
https://doi.org/10.3390/jfb16100389
Primary Topic
Facial Trauma and Fracture Management
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Plate Breakage After Mandibular Condylar Fracture Osteosynthesis

Marcin Kozakiewicz, Paulina Pruszyńska, Paulina Agier
Journal of Functional Biomaterials
Facial Trauma and Fracture Management
article

Plate Breakage After Mandibular Condylar Fracture Osteosynthesis

Marcin Kozakiewicz, Paulina Pruszyńska, Paulina Agier
article en

Abstract

Despite the significant ongoing development of fixation materials, plate breakages still occur after osteosynthesis of the mandibular condyles. The aim of this study is to demonstrate the complications caused by fixation material breakages in the hope of inspiring the development of new, more durable plates; we analyzed a total of 238 plates used for osteosynthesis in this anatomical region. Cases where compression screws were used as the sole fixation material were excluded. Plate breakage was found in six cases, which accounted for 2.52% of treated individuals. It seems that most plate breakages can be avoided by maintaining effective patient supervision for up to 6 months after surgery. Risk factors for breakage are identified and guidelines for improving the design of future plates are provided. By analyzing some plate design features, we provide some indications for improving their strength and improving their designs for use in this field.

Journal of Functional BiomaterialsVol. 16(10)
University of Łódź (PL), Medical University of Lodz (PL)
Uniwersytet Łódzki
Openalex Percentile: Top 54%
Facial Trauma and Fracture Management
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.