Spatiotemporal structure of SARS-CoV-2 mutational frequencies in wastewater samples from Ontario

Starting October 2021, the Ontario wastewater surveillance initiative has used next-generation sequencing (NGS) to monitor SARS-CoV-2 RNA in wastewater samples. The fragmented and heterogeneous nature of these data precludes using comparative methods that require full-length genome sequences. In this study, we investigate the utility of the inner product of the vectors of mutation frequencies to quantify the temporal and spatial structure of these data. Raw sequence data were trimmed and mapped to the SARS-CoV-2 reference genome to extract mutation frequencies and coverage statistics. These data were filtered for samples with incomplete metadata, positions with insufficient coverage (> 100 reads), or mutations with frequencies below 1%. For every pair of samples, we calculated the inner product of the respective mutation frequency vectors, and normalized the result to obtain a cosine distance. In total, we processed 1,619 samples from October 2021 to June 2023. The average depth was 7,693 reads, with mean coverage of 24,853 nt. A total of 241,078 mutations were detected in these samples. We restricted our analysis to 20 consecutive months with samples from at least one health region per month. A projection of the resulting cosine distance matrix revealed substantial temporal structure largely driven by the rapid spread of variants of concern. Genetic similarity, as quantified by the normalized dot product of mutation frequencies, was significantly negatively correlated with the geographic distance between sampling locations. These results suggest that spatial differentiation in the genomic variation of SARS-CoV-2 among wastewater samples can be measured, even at the relatively small scale of a single province.

Authors

Institutions

Publication Details

Journal
PLoS ONE
Published
2025-10-16
DOI
https://doi.org/10.1371/journal.pone.0333945
Primary Topic
SARS-CoV-2 detection and testing
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Spatiotemporal structure of SARS-CoV-2 mutational frequencies in wastewater samples from Ontario

Art F. Y. Poon, Valeria R. Parreira, Abayomi S. Olabode, Lawrence Goodridge et al.
PLoS ONE
SARS-CoV-2 detection and testing
article

Spatiotemporal structure of SARS-CoV-2 mutational frequencies in wastewater samples from Ontario

Art F. Y. Poon, Valeria R. Parreira, Abayomi S. Olabode, Lawrence Goodridge, Gopi Gugan, Christopher T. DeGroot, Opeyemi U. Lawal, Amber Fedynak, Linkang Zhang, Devan Becker, Melinda Precious, Wei Wang, Fozia Rizvi, Paula Magbor
article en

Abstract

Starting October 2021, the Ontario wastewater surveillance initiative has used next-generation sequencing (NGS) to monitor SARS-CoV-2 RNA in wastewater samples. The fragmented and heterogeneous nature of these data precludes using comparative methods that require full-length genome sequences. In this study, we investigate the utility of the inner product of the vectors of mutation frequencies to quantify the temporal and spatial structure of these data. Raw sequence data were trimmed and mapped to the SARS-CoV-2 reference genome to extract mutation frequencies and coverage statistics. These data were filtered for samples with incomplete metadata, positions with insufficient coverage (> 100 reads), or mutations with frequencies below 1%. For every pair of samples, we calculated the inner product of the respective mutation frequency vectors, and normalized the result to obtain a cosine distance. In total, we processed 1,619 samples from October 2021 to June 2023. The average depth was 7,693 reads, with mean coverage of 24,853 nt. A total of 241,078 mutations were detected in these samples. We restricted our analysis to 20 consecutive months with samples from at least one health region per month. A projection of the resulting cosine distance matrix revealed substantial temporal structure largely driven by the rapid spread of variants of concern. Genetic similarity, as quantified by the normalized dot product of mutation frequencies, was significantly negatively correlated with the geographic distance between sampling locations. These results suggest that spatial differentiation in the genomic variation of SARS-CoV-2 among wastewater samples can be measured, even at the relatively small scale of a single province.

PLoS ONEVol. 20(10)
Western University (CA), Canadian Institute for Public Safety Research and Treatment (CA), University of Windsor (CA), Wilfrid Laurier University (CA), University of Guelph (CA)
Openalex Percentile: Top 65%
SARS-CoV-2 detection and testing
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.