Hardware Implementation of a Real-Time Adaptive Time-Series Segmentation Algorithm for Intracortical Implants

Epilepsy affects over 50 million people worldwide, posing a significant clinical challenge, particularly for patients unresponsive to conventional treatments. Advances in neural implants with on-device algorithms are revolutionizing epilepsy management by enabling precise, real-time seizure detection and reducing the technical and financial burden of data transmission. The current trend advances towards the integration of a larger number of electrodes in neural implants, enhancing spatial resolution and broadening brain coverage. Consequently, the increasing data demands necessitate highly efficient processing to minimize transmission bandwidth and power consumption, ensuring the long-term viability of implantable systems. This work presents a novel approach using time-series segmentation (TSS) to extract labeled information from raw recordings. The algorithm explores multiple outlier detection methods with a heuristic low-complexity event classifier, and employs a multichannel consensus strategy to improve detection accuracy through multichannel agreement. This system enables high-performance seizure detection and segments local field potentials (LFP) into clinically relevant labels for interpretation and post-processing. Tested on microelectrode array (MEA) recordings from mouse hippocampus-cortex slices treated with 4-aminopyridine, the system demonstrated robust reliability. Implemented on a Pynq-Z2 board with a Zynq 7020 System-on-Chip, the algorithm requires minimal calibration, achieving 95% accuracy, 94% sensitivity, and a 0.03% FPR with a low power consumption of 128 mW for the best-performing outlier detector. By demonstrating the application of TSS to implantable device algorithms for on-device processing, this work advances towards more effective, personalized epilepsy treatments.

Authors

Institutions

Publication Details

Journal
IEEE Transactions on Biomedical Circuits and Systems
Published
2025-10-16
DOI
https://doi.org/10.1109/tbcas.2025.3622493
Primary Topic
Medical Image Segmentation Techniques
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Hardware Implementation of a Real-Time Adaptive Time-Series Segmentation Algorithm for Intracortical Implants

B. Linares-Barranco, Gabriella Panuccio, Gabriel Galeote‐Checa, Teresa Serrano‐Gotarredona
IEEE Transactions on Biomedical Circuits and Systems
Medical Image Segmentation Techniques
article

Hardware Implementation of a Real-Time Adaptive Time-Series Segmentation Algorithm for Intracortical Implants

B. Linares-Barranco, Gabriella Panuccio, Gabriel Galeote‐Checa, Teresa Serrano‐Gotarredona
article en

Abstract

Epilepsy affects over 50 million people worldwide, posing a significant clinical challenge, particularly for patients unresponsive to conventional treatments. Advances in neural implants with on-device algorithms are revolutionizing epilepsy management by enabling precise, real-time seizure detection and reducing the technical and financial burden of data transmission. The current trend advances towards the integration of a larger number of electrodes in neural implants, enhancing spatial resolution and broadening brain coverage. Consequently, the increasing data demands necessitate highly efficient processing to minimize transmission bandwidth and power consumption, ensuring the long-term viability of implantable systems. This work presents a novel approach using time-series segmentation (TSS) to extract labeled information from raw recordings. The algorithm explores multiple outlier detection methods with a heuristic low-complexity event classifier, and employs a multichannel consensus strategy to improve detection accuracy through multichannel agreement. This system enables high-performance seizure detection and segments local field potentials (LFP) into clinically relevant labels for interpretation and post-processing. Tested on microelectrode array (MEA) recordings from mouse hippocampus-cortex slices treated with 4-aminopyridine, the system demonstrated robust reliability. Implemented on a Pynq-Z2 board with a Zynq 7020 System-on-Chip, the algorithm requires minimal calibration, achieving 95% accuracy, 94% sensitivity, and a 0.03% FPR with a low power consumption of 128 mW for the best-performing outlier detector. By demonstrating the application of TSS to implantable device algorithms for on-device processing, this work advances towards more effective, personalized epilepsy treatments.

IEEE Transactions on Biomedical Circuits and SystemsVol. 20(1)
Italian Institute of Technology (IT), Instituto de Microelectrónica de Sevilla (ES)
Openalex Percentile: Top 71%
Medical Image Segmentation Techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.