Magnetic field sensing for 2D fault localization in underground power cables

Localizing faults in underground cables is a two-dimensional inverse problem, including the depth as the vertical dimension and the horizontal distance from the supply point. In this paper, a new approach based on magnetic field sensing is developed to accurately locate faults in underground cables without physically accessing them. Three types of fault are addressed, line-to-ground fault (LGF), leakage current fault (LCF), and line-to-line fault (LLF). Based on magnetic field sensing, the cable is first localized. Afterwards, the depth is calculated using the Quotient method and finally, the horizontal distance is determined using Kirchhoff's law (KVL). The simulation results show average errors of 5.25%, 4.77%, and 3.53% for LGF, LCF, and LLF. respectively, while the experimental results yield errors of 20% and 29% for LGF and LLF. These findings highlight the reliability of the proposed approach. Additionally, since the method requires only a single magnetic field sensing device with minimal computational effort, it offers a practical and cost-effective solution for the location of underground cable faults.

Authors

Institutions

Publication Details

Journal
PLoS ONE
Published
2025-10-16
DOI
https://doi.org/10.1371/journal.pone.0334515
Primary Topic
Power Systems Fault Detection
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Magnetic field sensing for 2D fault localization in underground power cables

Nayef Alqahtani, Ali H. Alenezi, Faheem Ali, Aamir Qamar et al.
PLoS ONE
Power Systems Fault Detection
article

Magnetic field sensing for 2D fault localization in underground power cables

Nayef Alqahtani, Ali H. Alenezi, Faheem Ali, Aamir Qamar, Hamid Ali
article en

Abstract

Localizing faults in underground cables is a two-dimensional inverse problem, including the depth as the vertical dimension and the horizontal distance from the supply point. In this paper, a new approach based on magnetic field sensing is developed to accurately locate faults in underground cables without physically accessing them. Three types of fault are addressed, line-to-ground fault (LGF), leakage current fault (LCF), and line-to-line fault (LLF). Based on magnetic field sensing, the cable is first localized. Afterwards, the depth is calculated using the Quotient method and finally, the horizontal distance is determined using Kirchhoff's law (KVL). The simulation results show average errors of 5.25%, 4.77%, and 3.53% for LGF, LCF, and LLF. respectively, while the experimental results yield errors of 20% and 29% for LGF and LLF. These findings highlight the reliability of the proposed approach. Additionally, since the method requires only a single magnetic field sensing device with minimal computational effort, it offers a practical and cost-effective solution for the location of underground cable faults.

PLoS ONEVol. 20(10)
Northern Border University (SA), COMSATS University Islamabad (PK), King Faisal University (SA), University of Engineering and Technology Peshawar (PK)
Openalex Percentile: Top 62%
Power Systems Fault Detection
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.