Torso synthetic CT generation by integrating deep learning and segmentation for FDG-PET/MR attenuation correction
<i>Introduction.</i>Positron Emission Tomography/Magnetic Resonance (<b>PET/MR</b>) offers benefits over PET/CT including simultaneous PET and MR acquisition, intrinsic spatial registration accuracy, MR-based functional information, and superior soft tissue contrast. However, accurate attenuation correction (<b>AC</b>) for PET remains challenging as MR signals do not directly correspond to attenuation. Using deep learning algorithms that learn complex relationships, we generate synthetic CT (<b>sCT</b>) from MR for AC. Our novel method for AC, merges deep learning with threshold-based segmentation, to produce an AC map for the entire torso from Dixon MR images, which heretofore has not been demonstrated.<i>Method</i>. Twenty-nine prospectively collected, paired FDG-PET/CT and MR datasets were used for training and validation using the U-net Residual Network conditional Generative Adversarial Network integrated with tissue segmentation (<b>URcGAN</b><sub><b>mod</b></sub>) from Dixon MR data. Our application focused on torso (base of the skull to mid-thigh) AC, a common but challenging field of view (FOV). Performance was compared to that of 4 previously published methods.<i>Results</i>. Using 15 paired datasets for training and 14 independent datasets for testing, the URcGAN<sub>mod</sub>generates an accurate torso sCT with a mean absolute difference of 32 ± 4 HU per voxel. When applied for AC for FDG images, and considering evaluable (SUV ≥ 0.1 g/ml) voxels across all regions of interest, absolute values of the differences were within 4.4% from those determined using the measured CT for AC. Reproducibility was excellent with less than 3.5% standard deviation. The results demonstrate the accuracy and precision of URcGAN<sub>mod</sub>method for torso sCT generation for quantitatively accurate MR-based AC (<b>MRAC</b>), exceeding the comparison methods.<i>Conclusion</i>. Combining deep learning and segmentation enhances MRAC accuracy in torso FDG-PET/MR, improves SUV accuracy throughout the torso, achieves less than 4.4% SUV error, and outperforms comparison methods. Given the excellent sCT and SUV accuracy and precision, our proposed method warrants further studies for quantitative longitudinal multicenter trials.
Authors
- Tithi Biswas (ORCID: https://orcid.org/0000-0002-9074-733X)
- Jennifer A. Dorth (ORCID: https://orcid.org/0000-0002-1112-3781)
- Yi Gu (ORCID: https://orcid.org/0000-0001-7962-9466)
- Theodore Arsenault (ORCID: https://orcid.org/0009-0005-2740-5934)
- Pengjiang Qian (ORCID: https://orcid.org/0000-0002-5596-3694)
- Bryan J. Traughber (ORCID: https://orcid.org/0000-0002-7391-6517)
- Steven Waggoner (ORCID: https://orcid.org/0000-0001-7037-4858)
- Atallah Baydoun (ORCID: https://orcid.org/0000-0003-0244-5583)
- Melanie Traughber
- Yizhang Jiang (ORCID: https://orcid.org/0000-0002-4558-9803)
- Kate Sandstrom
- Robert S. Jones (ORCID: https://orcid.org/0000-0002-9213-3657)
- Eleanor Harris (ORCID: https://orcid.org/0000-0002-7529-7473)
- John Nakayama
- Cheryl L. Thompson (ORCID: https://orcid.org/0000-0002-6896-2367)
- Jin Uk Heo (ORCID: https://orcid.org/0000-0001-9644-202X)
- Rose Al Helo (ORCID: https://orcid.org/0000-0003-1324-8710)
- Shujin Sun (ORCID: https://orcid.org/0000-0002-9324-1190)
- Min Yao (ORCID: https://orcid.org/0000-0001-7462-1318)
- Raymond Jr. F Muizc (ORCID: https://orcid.org/0000-0001-9986-4674)
Institutions
- Jiangnan University (CN)
- St. Luke's University Health Network (US)
- MetroHealth (US)
- Pennsylvania State University (US)
- Allegheny Health Network (US)
- Cleveland Clinic (US)
- Mayo Clinic (US)
- University Hospitals of Cleveland (US)
- Anna Needs Neuroblastoma Answers (US)
- Mayo Clinic in Arizona (US)
- Mayo Clinic in Florida (US)
- Case Western Reserve University (US)
- Guilford College (US)
- Penn State Milton S. Hershey Medical Center (US)
Publication Details
- Journal
- Biomedical Physics & Engineering Express
- Published
- 2025-10-16
- DOI
- https://doi.org/10.1088/2057-1976/ae13ff
- Primary Topic
- Medical Imaging Techniques and Applications
- Type
- article
- Field-Weighted Citation Impact
- 0.00