Assessing Adequacy of Marker Ball Placement in Preoperative Pelvic X-rays: Are We Missing the Mark?

Introduction Accurate preoperative templating in hip arthroplasty depends on correct marker ball placement during anteroposterior (AP) pelvic radiographs. Misplacement can compromise prediction of femoral offset and leg length, increasing operative complexity and complication risk. This closed-loop audit evaluated marker ball adequacy in patients with intracapsular neck of femur fractures and assessed the impact of targeted interventions. Methods A retrospective audit was conducted at Poole General Hospital, United Kingdom. Patients with radiologically confirmed intracapsular fractures between January and May 2025 were included; exclusions were extracapsular fractures, age <18, open fractures, and prior contralateral hip replacement. Audit standards required marker balls to be entirely visible and positioned between femurs, inferior to the symphysis pubis, with an agreed compliance target of 80%. Interventions included educational presentations, poster reminders, and a mandatory checklist. A re-audit was performed from June 1-30, 2025. Statistical analysis was performed using chi-square testing. Results Cycle one included 60 cases, with marker balls present in 45% (n=27). Of these, 59% (n=16) were entirely visible and 41% (n=11) were correctly positioned, yielding overall compliance of 59%. Following interventions, cycle two (n=50) demonstrated significant improvement: marker balls present in 78% (n=39), with 84% (n=33) entirely visible (p=0.042) and 82% (n=32) correctly positioned (p=0.0014). Overall compliance increased to 80%, meeting the target standard. Conclusion Simple, low-cost educational measures significantly improved marker ball placement in pelvic radiographs for hip fracture patients. Embedding such interventions into routine radiography practice enhances the accuracy of preoperative templating, promotes patient safety, and reduces medico-legal risk. Ongoing audit and education are essential to sustain improvements.

Authors

Institutions

Publication Details

Journal
Cureus
Published
2025-10-16
DOI
https://doi.org/10.7759/cureus.94736
Primary Topic
Orthopaedic implants and arthroplasty
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Assessing Adequacy of Marker Ball Placement in Preoperative Pelvic X-rays: Are We Missing the Mark?

Talha Ahmed, Abdullah Khan Durrani, Irfan Afzal, Antony Raymond et al.
Cureus
Orthopaedic implants and arthroplasty
article

Assessing Adequacy of Marker Ball Placement in Preoperative Pelvic X-rays: Are We Missing the Mark?

Talha Ahmed, Abdullah Khan Durrani, Irfan Afzal, Antony Raymond, Hassan Imtiaz, Georgios Kouklidis, Parth Shah, A. Z. M. Rezaul Karim, Adam Khan Rahim, Kunjan Barot
article en

Abstract

Introduction Accurate preoperative templating in hip arthroplasty depends on correct marker ball placement during anteroposterior (AP) pelvic radiographs. Misplacement can compromise prediction of femoral offset and leg length, increasing operative complexity and complication risk. This closed-loop audit evaluated marker ball adequacy in patients with intracapsular neck of femur fractures and assessed the impact of targeted interventions. Methods A retrospective audit was conducted at Poole General Hospital, United Kingdom. Patients with radiologically confirmed intracapsular fractures between January and May 2025 were included; exclusions were extracapsular fractures, age <18, open fractures, and prior contralateral hip replacement. Audit standards required marker balls to be entirely visible and positioned between femurs, inferior to the symphysis pubis, with an agreed compliance target of 80%. Interventions included educational presentations, poster reminders, and a mandatory checklist. A re-audit was performed from June 1-30, 2025. Statistical analysis was performed using chi-square testing. Results Cycle one included 60 cases, with marker balls present in 45% (n=27). Of these, 59% (n=16) were entirely visible and 41% (n=11) were correctly positioned, yielding overall compliance of 59%. Following interventions, cycle two (n=50) demonstrated significant improvement: marker balls present in 78% (n=39), with 84% (n=33) entirely visible (p=0.042) and 82% (n=32) correctly positioned (p=0.0014). Overall compliance increased to 80%, meeting the target standard. Conclusion Simple, low-cost educational measures significantly improved marker ball placement in pelvic radiographs for hip fracture patients. Embedding such interventions into routine radiography practice enhances the accuracy of preoperative templating, promotes patient safety, and reduces medico-legal risk. Ongoing audit and education are essential to sustain improvements.

CureusVol. 17(10)
Poole Hospital (GB), Poole Hospital NHS Foundation Trust (GB)
Openalex Percentile: Top 54%
Orthopaedic implants and arthroplasty
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.