Corrigendum: Monte Carlo calculation of <sup>119</sup>Sb microscale absorbed dose using cascaded and averaged Auger electron spectra (2025 <i>Phys. Med. Biol.</i> 70 115022)

An error in the original manuscript was identified regarding the use of Auger transition data from the Evaluated Atomic Data Library (EADL). In the original publication, electron energies and transition probabilities for Auger, Coster-Kronig, and super Coster-Kronig transitions were retrieved from the EADL for Sb in order to compare with data for119Sbavailable from the Medical Internal Radiation Dose (MIRD) RADTABS program. However, data for Sn should have been retrieved instead. Here we present a corrected comparison of individual transitions using the EADL transition data for the daughter atoms. Our findings reflect a much-improved comparison between MIRD and EADL. The other conclusions in the original publication are not affected. We regret that this error was caught neither in the preparation of the manuscript nor in the peer review process, and we apologize for any confusion we may have caused.

Authors

Institutions

Publication Details

Journal
Physics in Medicine and Biology
Published
2025-10-16
DOI
https://doi.org/10.1088/1361-6560/ae0f6f
Primary Topic
Radiation Therapy and Dosimetry
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Corrigendum: Monte Carlo calculation of 119Sb microscale absorbed dose using cascaded and averaged Auger electron spectra (2025 Phys. Med. Biol. 70 115022)

A. V. Zwaniga, Eric Da Silva, Raffi Karshafian, James L Gräfe et al.
Physics in Medicine and Biology
Radiation Therapy and Dosimetry
article

Corrigendum: Monte Carlo calculation of 119Sb microscale absorbed dose using cascaded and averaged Auger electron spectra (2025 Phys. Med. Biol. 70 115022)

A. V. Zwaniga, Eric Da Silva, Raffi Karshafian, James L Gräfe, Humza Nusrat
article en

Abstract

An error in the original manuscript was identified regarding the use of Auger transition data from the Evaluated Atomic Data Library (EADL). In the original publication, electron energies and transition probabilities for Auger, Coster-Kronig, and super Coster-Kronig transitions were retrieved from the EADL for Sb in order to compare with data for119Sbavailable from the Medical Internal Radiation Dose (MIRD) RADTABS program. However, data for Sn should have been retrieved instead. Here we present a corrected comparison of individual transitions using the EADL transition data for the daughter atoms. Our findings reflect a much-improved comparison between MIRD and EADL. The other conclusions in the original publication are not affected. We regret that this error was caught neither in the preparation of the manuscript nor in the peer review process, and we apologize for any confusion we may have caused.

Physics in Medicine and BiologyVol. 70(20)
St. Michael's Hospital (CA), Henry Ford Health System (US), Henry Ford Hospital (US), Dr. H. Bliss Murphy Cancer Centre (CA), Unity Health Toronto, Toronto Metropolitan University (CA)
Openalex Percentile: Top 58%
Radiation Therapy and Dosimetry
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.