Numerical Simulation and Thermal Efficiency Assessment of Variatropic-Type Multi-Layer Exterior Wall Panels

This study presents a theoretical analysis of the effectiveness of the use of variatropic concretes in multi-layer panel structures of buildings in terms of heat transfer. Theoretical analysis was performed with the aid of the modern numerical modeling software package ELCUT 6.6 and the computer algebra system Maple, which helped improve the reliability of the calculations. The results of this study of the thermophysical parameters of multi-layer panels using variatropic concrete showed that an increase in the degree of variatropy contributes to a rise in the temperature on the inner surface of the panel from 17.94 °C (traditional panel) to 18.87 °C (the most variatropic panel, Scheme 4), which improves indoor comfort conditions and reduces the risk of condensation. Additionally, it is possible to reduce the thickness of the insulation layer without compromising thermal efficiency. The high thermal inertia (D > 7) of variatropic panels ensures the accumulation and retention of heat, which has a positive effect on energy consumption during the heating season. The moisture regime of the studied structures meets regulatory criteria for preventing moisture accumulation, thereby increasing panel durability and eliminating conditions for mold formation or structural degradation. The air permeability performance of the panels also complies with the standards, while the dense outer concrete layers provide additional protection against air infiltration, stabilizing both thermal and moisture balance. The calculated thermal resistance of variatropic panels (Schemes 3 and 4) exceeded the standard requirement (3.20 m2·°C/W) by 1.2 and 1.74 times, respectively. Thus, it was established that the application of the variatropic principle in panel design ensures a more rational distribution of temperature fields, which results in reduced heat losses and improved thermal stability of exterior enclosures. This approach develops new design solutions focused on improving the energy efficiency of buildings and reducing material costs, which is consistent with current trends in Functionally Graded Design (FGD).

Authors

Institutions

Publication Details

Journal
Buildings
Published
2025-10-15
DOI
https://doi.org/10.3390/buildings15203717
Primary Topic
Masonry and Concrete Structural Analysis
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Numerical Simulation and Thermal Efficiency Assessment of Variatropic-Type Multi-Layer Exterior Wall Panels

Olga Miryuk, Nurlan Zhangabay, Murat Rakhimov, Myrzabek Yermakhanov et al.
Buildings
Masonry and Concrete Structural Analysis
article

Numerical Simulation and Thermal Efficiency Assessment of Variatropic-Type Multi-Layer Exterior Wall Panels

Olga Miryuk, Nurlan Zhangabay, Murat Rakhimov, Myrzabek Yermakhanov, Askhat Rakhimov, Kamilya Maikotova
article en

Abstract

This study presents a theoretical analysis of the effectiveness of the use of variatropic concretes in multi-layer panel structures of buildings in terms of heat transfer. Theoretical analysis was performed with the aid of the modern numerical modeling software package ELCUT 6.6 and the computer algebra system Maple, which helped improve the reliability of the calculations. The results of this study of the thermophysical parameters of multi-layer panels using variatropic concrete showed that an increase in the degree of variatropy contributes to a rise in the temperature on the inner surface of the panel from 17.94 °C (traditional panel) to 18.87 °C (the most variatropic panel, Scheme 4), which improves indoor comfort conditions and reduces the risk of condensation. Additionally, it is possible to reduce the thickness of the insulation layer without compromising thermal efficiency. The high thermal inertia (D > 7) of variatropic panels ensures the accumulation and retention of heat, which has a positive effect on energy consumption during the heating season. The moisture regime of the studied structures meets regulatory criteria for preventing moisture accumulation, thereby increasing panel durability and eliminating conditions for mold formation or structural degradation. The air permeability performance of the panels also complies with the standards, while the dense outer concrete layers provide additional protection against air infiltration, stabilizing both thermal and moisture balance. The calculated thermal resistance of variatropic panels (Schemes 3 and 4) exceeded the standard requirement (3.20 m2·°C/W) by 1.2 and 1.74 times, respectively. Thus, it was established that the application of the variatropic principle in panel design ensures a more rational distribution of temperature fields, which results in reduced heat losses and improved thermal stability of exterior enclosures. This approach develops new design solutions focused on improving the energy efficiency of buildings and reducing material costs, which is consistent with current trends in Functionally Graded Design (FGD).

BuildingsVol. 15(20)
Rudny Industrial Institute (KZ), Abylkas Saginov Karaganda Technical University (KZ), M.Auezov South Kazakhstan State University (KZ)
Openalex Percentile: Top 69%
Masonry and Concrete Structural Analysis
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.