The Fracture Strength of Acrylic Palatal Prostheses After Microwave and Chlorhexidine Disinfection: A Comparative In Vitro Study

Background/Objectives: Disinfection of removable prostheses is essential for controlling oral infections, yet the methods employed may compromise the mechanical reliability of denture base materials. This study evaluated the effect of microwave irradiation and immersion in 0.2% chlorhexidine solution on the fracture strength of three commonly used acrylic denture bases. Methods: Forty-five standardised maxillary palatal denture bases were fabricated from cross-linked conventional, high-impact, and light-cured acrylic resins. The specimens were divided equally into three treatment groups: water storage (control), immersion in 0.2% chlorhexidine solution for 30 min twice weekly, and microwave disinfection at 650 W for three minutes, each continued for four weeks. Fracture strength was determined by using the Universal testing machine. The data were analysed with one-way ANOVA followed by Bonferroni post hoc testing. Results: Cross-linked and high-impact acrylic resins exhibited significantly greater fracture strength than light-cured acrylics (p < 0.001). The overall ANOVA showed no statistically significant differences among disinfection methods (p = 0.069); however, post hoc comparisons revealed significant reductions in fracture strength within specific material groups following microwave disinfection. This effect was most pronounced in the light-cured group, whereas immersion in chlorhexidine produced no significant changes. Notably, the fracture strength of all groups remained above clinically acceptable thresholds. Conclusions: Microwave disinfection negatively influences the mechanical integrity of acrylic denture bases, particularly those fabricated from light-cured resins. In contrast, immersion in 0.2% chlorhexidine preserves fracture strength, supporting its use as a safe and effective protocol for routine disinfection in dental practice.

Authors

Institutions

Publication Details

Journal
Oral
Published
2025-10-13
DOI
https://doi.org/10.3390/oral5040078
Primary Topic
Dental materials and restorations
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

The Fracture Strength of Acrylic Palatal Prostheses After Microwave and Chlorhexidine Disinfection: A Comparative In Vitro Study

Jwan Fateh Abdulkareem, Saja Kareem Esmael, Faten Khalid Al-Kadi
Oral
Dental materials and restorations
article

The Fracture Strength of Acrylic Palatal Prostheses After Microwave and Chlorhexidine Disinfection: A Comparative In Vitro Study

Jwan Fateh Abdulkareem, Saja Kareem Esmael, Faten Khalid Al-Kadi
article en

Abstract

Background/Objectives: Disinfection of removable prostheses is essential for controlling oral infections, yet the methods employed may compromise the mechanical reliability of denture base materials. This study evaluated the effect of microwave irradiation and immersion in 0.2% chlorhexidine solution on the fracture strength of three commonly used acrylic denture bases. Methods: Forty-five standardised maxillary palatal denture bases were fabricated from cross-linked conventional, high-impact, and light-cured acrylic resins. The specimens were divided equally into three treatment groups: water storage (control), immersion in 0.2% chlorhexidine solution for 30 min twice weekly, and microwave disinfection at 650 W for three minutes, each continued for four weeks. Fracture strength was determined by using the Universal testing machine. The data were analysed with one-way ANOVA followed by Bonferroni post hoc testing. Results: Cross-linked and high-impact acrylic resins exhibited significantly greater fracture strength than light-cured acrylics (p < 0.001). The overall ANOVA showed no statistically significant differences among disinfection methods (p = 0.069); however, post hoc comparisons revealed significant reductions in fracture strength within specific material groups following microwave disinfection. This effect was most pronounced in the light-cured group, whereas immersion in chlorhexidine produced no significant changes. Notably, the fracture strength of all groups remained above clinically acceptable thresholds. Conclusions: Microwave disinfection negatively influences the mechanical integrity of acrylic denture bases, particularly those fabricated from light-cured resins. In contrast, immersion in 0.2% chlorhexidine preserves fracture strength, supporting its use as a safe and effective protocol for routine disinfection in dental practice.

OralVol. 5(4)
University of Baghdad (IQ), University of Sulaimani (IQ)
Openalex Percentile: Top 69%
Dental materials and restorations
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.