Automated body weight measurement using computed tomography

Computed tomography (CT) images provide detailed information on tissue composition and density. Body weight estimation from CT can be highly relevant in emergency and forensic contexts where conventional weighing is impractical or unavailable-for example, due to unconscious or immobilized patients, lack of appropriate equipment, or the necessity to preserve forensic trace evidence. An automated method for body weight estimation using antemortem and postmortem CT data from clinical scanners was evaluated. Two retrospective cohorts were included: 30 forensic postmortem whole-body CT scans and 66 clinical torso CT scans. Tissue segmentation applied predefined Hounsfield Unit thresholds for fat, muscle, and bone, with voxel volumes multiplied by corresponding tissue densities to calculate weight. In forensic cases, CT-derived weights differed by - 1.26 ± 2.58 kg (median: - 1.15 kg) from measured weights. In clinical cases, torso weight was extrapolated to total body weight using a corrected scaling factor that accounted for body and scan length, resulting in an average difference of 0.53 ± 4.62 kg (median: 0.23 kg). Linear regression demonstrated strong correlations (R<sup>2</sup> = 0.97/0.96 forensic/clinical). These findings indicate that routinely acquired CT scans enable accurate, automated, and retrospective body weight estimation, providing a non-invasive alternative when direct measurement is not feasible while simultaneously allowing body composition analysis.

Authors

Institutions

Publication Details

Journal
Scientific Reports
Published
2025-10-15
DOI
https://doi.org/10.1038/s41598-025-24060-1
Citations
1
Primary Topic
Body Composition Measurement Techniques
Type
article
Field-Weighted Citation Impact
1.16

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Automated body weight measurement using computed tomography

Andreas Heinrich, Rainer Koch, Holger Muggenthaler, Sebastian Schenkl
1 citations
Scientific Reports
Body Composition Measurement Techniques
1.16
article

Automated body weight measurement using computed tomography

Andreas Heinrich, Rainer Koch, Holger Muggenthaler, Sebastian Schenkl
article en
1 citations

Abstract

Computed tomography (CT) images provide detailed information on tissue composition and density. Body weight estimation from CT can be highly relevant in emergency and forensic contexts where conventional weighing is impractical or unavailable-for example, due to unconscious or immobilized patients, lack of appropriate equipment, or the necessity to preserve forensic trace evidence. An automated method for body weight estimation using antemortem and postmortem CT data from clinical scanners was evaluated. Two retrospective cohorts were included: 30 forensic postmortem whole-body CT scans and 66 clinical torso CT scans. Tissue segmentation applied predefined Hounsfield Unit thresholds for fat, muscle, and bone, with voxel volumes multiplied by corresponding tissue densities to calculate weight. In forensic cases, CT-derived weights differed by - 1.26 ± 2.58 kg (median: - 1.15 kg) from measured weights. In clinical cases, torso weight was extrapolated to total body weight using a corrected scaling factor that accounted for body and scan length, resulting in an average difference of 0.53 ± 4.62 kg (median: 0.23 kg). Linear regression demonstrated strong correlations (R<sup>2</sup> = 0.97/0.96 forensic/clinical). These findings indicate that routinely acquired CT scans enable accurate, automated, and retrospective body weight estimation, providing a non-invasive alternative when direct measurement is not feasible while simultaneously allowing body composition analysis.

Scientific ReportsVol. 15(1)
Jena University Hospital (DE), Friedrich Schiller University Jena (DE)
Deutsche Forschungsgemeinschaft
Openalex Percentile: Top 17%
Body Composition Measurement Techniques
1.16
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Automated body weight measurement using computed tomography — Andreas Heinrich, Rainer Koch, et al. · Scientific Reports (2025) | TGRS Research Map | TGRS