Affinity peptide-based magnetic micromotors for rapid, selective, ultra-sensitive, and reliable quantification of SARS-CoV-2 spike protein in microliter-scale nasopharyngeal and plasma samples from infected patients

Monitoring respiratory viruses is paramount to reducing the spread of the virus and associated costs, especially during the winter months. Here, we present magnetically propelled MoS<sub>2</sub>/Ni micromotors modified with a rhodamine B-labelled peptide that binds to the receptor-binding domain (RBD) on the S1 subunit of the spike protein (S). The approach uses an "on-the-fly" OFF-ON fluorescence method to detect the SARS-CoV-2 virus in two types of samples: nasopharyngeal and plasma samples, both types previously tested by molecular methods, and plasma samples additionally analyzed by serological assays. The micromotors move through the sample, inducing enhanced fluid mixing and increasing the number of peptide-spike protein biorecognition events, yielding an efficient operation using just 1 μL of sample. The adsorbed peptide on MoS<sub>2</sub> (OFF state) desorbs from the micromotors, due to interaction rhodamine B-labelled peptide-spike protein resulting in an increase in target-dependent fluorescence intensity in the solution measured using fluorescence microscopy (ON state). The approach takes just 1 min, displaying a linear range of 0.006-50 ng/mL with an excellent limit of detection of 1.8 pg/mL. The good agreement between the main infection indicators from nasopharyngeal and plasma samples, as measured by molecular and serological tests in the hospital, and the protein S concentration, as measured by our micromotor approach, demonstrates the applicability of the method for the rapid diagnosis of respiratory infections, opening new avenues for the diagnosis of respiratory infections. While the potency of the micromotor approach is demonstrated here, novel integration approaches are also envisioned in the near future.

Authors

Institutions

Publication Details

Journal
Biosensors and Bioelectronics
Published
2025-10-15
DOI
https://doi.org/10.1016/j.bios.2025.118098
Primary Topic
SARS-CoV-2 detection and testing
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Affinity peptide-based magnetic micromotors for rapid, selective, ultra-sensitive, and reliable quantification of SARS-CoV-2 spike protein in microliter-scale nasopharyngeal and plasma samples from infected patients

Beatriz Jurado‐Sánchez, Felipe Pérez‐García, Tamara Postigo-Casado, Jesús F. Bermejo-Martín et al.
Biosensors and Bioelectronics
SARS-CoV-2 detection and testing
article

Affinity peptide-based magnetic micromotors for rapid, selective, ultra-sensitive, and reliable quantification of SARS-CoV-2 spike protein in microliter-scale nasopharyngeal and plasma samples from infected patients

Beatriz Jurado‐Sánchez, Felipe Pérez‐García, Tamara Postigo-Casado, Jesús F. Bermejo-Martín, Alberto Escarpa, A. Guillermo Rodr'iguez-Castillo
article en

Abstract

Monitoring respiratory viruses is paramount to reducing the spread of the virus and associated costs, especially during the winter months. Here, we present magnetically propelled MoS<sub>2</sub>/Ni micromotors modified with a rhodamine B-labelled peptide that binds to the receptor-binding domain (RBD) on the S1 subunit of the spike protein (S). The approach uses an "on-the-fly" OFF-ON fluorescence method to detect the SARS-CoV-2 virus in two types of samples: nasopharyngeal and plasma samples, both types previously tested by molecular methods, and plasma samples additionally analyzed by serological assays. The micromotors move through the sample, inducing enhanced fluid mixing and increasing the number of peptide-spike protein biorecognition events, yielding an efficient operation using just 1 μL of sample. The adsorbed peptide on MoS<sub>2</sub> (OFF state) desorbs from the micromotors, due to interaction rhodamine B-labelled peptide-spike protein resulting in an increase in target-dependent fluorescence intensity in the solution measured using fluorescence microscopy (ON state). The approach takes just 1 min, displaying a linear range of 0.006-50 ng/mL with an excellent limit of detection of 1.8 pg/mL. The good agreement between the main infection indicators from nasopharyngeal and plasma samples, as measured by molecular and serological tests in the hospital, and the protein S concentration, as measured by our micromotor approach, demonstrates the applicability of the method for the rapid diagnosis of respiratory infections, opening new avenues for the diagnosis of respiratory infections. While the potency of the micromotor approach is demonstrated here, novel integration approaches are also envisioned in the near future.

Biosensors and BioelectronicsVol. 292
Universidad de Alcalá (ES), Centro de Investigación Biomédica en Red (ES), Instituto de Investigación Biomédica de Salamanca (ES)
Openalex Percentile: Top 65%
SARS-CoV-2 detection and testing
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.