Preliminary Feasibility Study of Glucose Sensing by Permittivity Measurements in the RF Range

Continuous blood glucose monitoring is an essential need for diabetes patients. The preferred modality for glucose sensing would be non-invasive. Permittivity of a material can be measured non-invasively, and it depends on the material constituents. Accordingly, it has been proposed that glucose concentration could be measured by measuring the permittivity of the biofluids. However, the relevance of permittivity as a biomarker depends on the permittivity contrast between various physiological concentrations of glucose. In order to examine the feasibility of such sensing in the radiofrequency (RF) range, we measured the permittivity of glucose solutions in physiological saline. The results show that the permittivity variation within the physiological range of glucose concentrations is too low to be detectable using the open-ended coaxial probe below a few GHz. The results contribute to the understanding of the limitations of blood glucose monitoring by permittivity measurements using an open-ended coaxial probe.

Authors

Institutions

Publication Details

Published
2025-09-15
DOI
https://doi.org/10.1109/elmar66948.2025.11194042
Primary Topic
Microfluidic and Capillary Electrophoresis Applications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Preliminary Feasibility Study of Glucose Sensing by Permittivity Measurements in the RF Range

Antonio Šarolić, Anton Kordić, Anđela Matković, Vedrana Čikeš Čulić et al.
Microfluidic and Capillary Electrophoresis Applications
article

Preliminary Feasibility Study of Glucose Sensing by Permittivity Measurements in the RF Range

Antonio Šarolić, Anton Kordić, Anđela Matković, Vedrana Čikeš Čulić, Matea Paradžik
article en

Abstract

Continuous blood glucose monitoring is an essential need for diabetes patients. The preferred modality for glucose sensing would be non-invasive. Permittivity of a material can be measured non-invasively, and it depends on the material constituents. Accordingly, it has been proposed that glucose concentration could be measured by measuring the permittivity of the biofluids. However, the relevance of permittivity as a biomarker depends on the permittivity contrast between various physiological concentrations of glucose. In order to examine the feasibility of such sensing in the radiofrequency (RF) range, we measured the permittivity of glucose solutions in physiological saline. The results show that the permittivity variation within the physiological range of glucose concentrations is too low to be detectable using the open-ended coaxial probe below a few GHz. The results contribute to the understanding of the limitations of blood glucose monitoring by permittivity measurements using an open-ended coaxial probe.

University Hospital Centre Zagreb (HR), University of Split (HR)
Openalex Percentile: Top 72%
Microfluidic and Capillary Electrophoresis Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.