A Sequence Component Protection Method Based on Differential Current Increment

The transformer is a critical component in power systems, and studying fault protection methods is essential to prevent severe damage caused by short-circuit faults. Existing protection research primarily focuses on the characteristic analysis and identification of magnetizing inrush current. This involves constructing transformer models to investigate the generation mechanism of magnetizing inrush and examining the differences between inrush current and fault current, thereby reducing the likelihood of maloperation in protection schemes. However, in practical scenarios, faults often originate from minor inter-turn short circuits that progressively develop into more severe failures. Investigating protection strategies for such incipient faults can effectively prevent their escalation. Therefore, this paper proposes a sequence component protection method based on differential current increment. When the positive and negative-sequence components of the differential current increment are approximately equal and both exceed a predefined threshold, the method identifies a minor short-circuit fault. This enables the protection device to be triggered in the early stage of the fault, thereby preventing further fault escalation.

Authors

Institutions

Publication Details

Published
2025-08-15
DOI
https://doi.org/10.1109/iccepe66357.2025.11193244
Primary Topic
VLSI and Analog Circuit Testing
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A Sequence Component Protection Method Based on Differential Current Increment

Peilong Chen, Jun Liu, Shurong Xu, Kun Li et al.
VLSI and Analog Circuit Testing
article

A Sequence Component Protection Method Based on Differential Current Increment

Peilong Chen, Jun Liu, Shurong Xu, Kun Li, Kejie Huang, Qi Yang, Xianyin Mao, Linyu Huang
article en

Abstract

The transformer is a critical component in power systems, and studying fault protection methods is essential to prevent severe damage caused by short-circuit faults. Existing protection research primarily focuses on the characteristic analysis and identification of magnetizing inrush current. This involves constructing transformer models to investigate the generation mechanism of magnetizing inrush and examining the differences between inrush current and fault current, thereby reducing the likelihood of maloperation in protection schemes. However, in practical scenarios, faults often originate from minor inter-turn short circuits that progressively develop into more severe failures. Investigating protection strategies for such incipient faults can effectively prevent their escalation. Therefore, this paper proposes a sequence component protection method based on differential current increment. When the positive and negative-sequence components of the differential current increment are approximately equal and both exceed a predefined threshold, the method identifies a minor short-circuit fault. This enables the protection device to be triggered in the early stage of the fault, thereby preventing further fault escalation.

Guizhou Electric Power Design and Research Institute (CN)
Openalex Percentile: Top 68%
VLSI and Analog Circuit Testing
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

A Sequence Component Protection Method Based on Differential Current Increment — Peilong Chen, Jun Liu, et al. · (2025) | TGRS Research Map | TGRS