Development of a Multi-Modal Control Architecture for a Cable-Actuated Ankle Exoskeleton

This work presents a lightweight, cable-actuated ankle exoskeleton with hip-mounted motors and a dual-loop controller (outer PID for joint angle, inner PI for current) to deliver precise, phase-coherent assistance. Smooth reference trajectories are generated via a half-sine interpolation algorithm that ensures continuous velocity/acceleration and limits torque ripple. Control performance was evaluated on bench tests in which joint angles and actuator currents were logged; tracking accuracy was quantified using RMSE for both stepwise (gait-inspired) and sinusoidal commands, with the drive cable kept under constant tension. The architecture achieved sub-degree errors without overshoot or sustained oscillations, confirming stable assistance across dorsiflexion and plantarflexion. A remaining limitation is reduced responsiveness during high-frequency transitions due to inner-loop bandwidth constraints.

Authors

Institutions

Publication Details

Published
2025-08-10
DOI
https://doi.org/10.1109/wrcsara68202.2025.11194957
Primary Topic
Stroke Rehabilitation and Recovery
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Development of a Multi-Modal Control Architecture for a Cable-Actuated Ankle Exoskeleton

Olivier Bruneau, Hang Su, Samer Alfayad, Etienne Largeteau et al.
Stroke Rehabilitation and Recovery
article

Development of a Multi-Modal Control Architecture for a Cable-Actuated Ankle Exoskeleton

Olivier Bruneau, Hang Su, Samer Alfayad, Etienne Largeteau, Bangaly Conté
article en

Abstract

This work presents a lightweight, cable-actuated ankle exoskeleton with hip-mounted motors and a dual-loop controller (outer PID for joint angle, inner PI for current) to deliver precise, phase-coherent assistance. Smooth reference trajectories are generated via a half-sine interpolation algorithm that ensures continuous velocity/acceleration and limits torque ripple. Control performance was evaluated on bench tests in which joint angles and actuator currents were logged; tracking accuracy was quantified using RMSE for both stepwise (gait-inspired) and sinusoidal commands, with the drive cable kept under constant tension. The architecture achieved sub-degree errors without overshoot or sustained oscillations, confirming stable assistance across dorsiflexion and plantarflexion. A remaining limitation is reduced responsiveness during high-frequency transitions due to inner-loop bandwidth constraints.

Université Paris-Saclay (FR)
Openalex Percentile: Top 64%
Stroke Rehabilitation and Recovery
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Development of a Multi-Modal Control Architecture for a Cable-Actuated Ankle Exoskeleton — Olivier Bruneau, Hang Su, et al. · (2025) | TGRS Research Map | TGRS