SI-Traceability of XRD Residual Stress Data by Using Fe Kα Radiation

Abstract XRD residual stress analyses by means of the conventional sin2ψ-method in accordance with standards EN 15305 or ASTM E2860 require well-aligned and calibrated X-ray diffractometers. The qualification of an X-ray diffractometer is performed by measurements of a stress-free powder sample and a certified ILQ reference sample from round robin experiments. In order to obtain reliable qualification results, the traceability of residual stress data to SI units is optimal, which can be achieved via Standard Reference Material 660c (LaB6) from NIST. However, in many cases, such as the traditional residual stress analysis of ferritic steel samples using Cr Kα radiation, the peak positions and intensities of LaB6 are unfavorable for SI-traceability measurements. The technical difficulties arising from this condition can be overcome by the application of Fe Kα radiation providing a diffraction peak of LaB6 close to the ones of common materials. This work quantitatively investigates the usability of Fe Kα radiation for XRD residual stress analyses including SI-traceability of stress-free powder samples based on LaB6. Moreover, its potential for multi-phase residual stress determination in duplex steels is demonstrated as a laboratory application example.

Authors

Institutions

Publication Details

Published
2025-10-15
DOI
https://doi.org/10.31399/asm.cp.icrs2025p0022
Primary Topic
Fusion materials and technologies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

SI-Traceability of XRD Residual Stress Data by Using Fe Kα Radiation

Mikko Palosaari, Jonathan Mohan, Sebastian Send
Fusion materials and technologies
article

SI-Traceability of XRD Residual Stress Data by Using Fe Kα Radiation

Mikko Palosaari, Jonathan Mohan, Sebastian Send
article en

Abstract

Abstract XRD residual stress analyses by means of the conventional sin2ψ-method in accordance with standards EN 15305 or ASTM E2860 require well-aligned and calibrated X-ray diffractometers. The qualification of an X-ray diffractometer is performed by measurements of a stress-free powder sample and a certified ILQ reference sample from round robin experiments. In order to obtain reliable qualification results, the traceability of residual stress data to SI units is optimal, which can be achieved via Standard Reference Material 660c (LaB6) from NIST. However, in many cases, such as the traditional residual stress analysis of ferritic steel samples using Cr Kα radiation, the peak positions and intensities of LaB6 are unfavorable for SI-traceability measurements. The technical difficulties arising from this condition can be overcome by the application of Fe Kα radiation providing a diffraction peak of LaB6 close to the ones of common materials. This work quantitatively investigates the usability of Fe Kα radiation for XRD residual stress analyses including SI-traceability of stress-free powder samples based on LaB6. Moreover, its potential for multi-phase residual stress determination in duplex steels is demonstrated as a laboratory application example.

Stresstech (Finland) (FI), Mössner (Germany) (DE)
Openalex Percentile: Top 77%
Fusion materials and technologies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.