Quantifying protons in triple conducting perovskite-type oxides via laser-induced breakdown spectroscopy – A comparative validation approach

Proton-conducting oxides are promising materials for renewable energy technologies - e.g. as electrolytes and electrodes in solid oxide cells or membranes for hydrogen purification. Particularly relevant for these applications are perovskites, which can accommodate high concentrations of protons in their crystal structure. However, quantifying the proton concentration is challenging under reducing conditions, OH uptake and oxygen loss occur simultaneously, causing compensating weight changes. Thus, attributing weight changes directly to OH uptake is not possible without complementary techniques for validation. Here, we focus on quantifying the proton concentration in the triple conducting perovskite-type oxide BaFe 0.85 Y 0.15 O 3– δ (BFY) under various oxidation and protonation states. To do so, we introduce an alternative analytical method, which is capable of direct proton detection in perovskites and well-suited for in-situ quantification: Laser-induced breakdown spectroscopy (LIBS). This technique analyses characteristic emissions from the plasma generated by UV-laser irradiation of the material. Validation of results involved gravimetry and Fourier-transform infrared spectroscopy (FT-IR). While gravimetry was used to determine the proton concentration under special experimental conditions, FT-IR spectroscopy was used to distinguish the protons – located in the perovskite structure in the form of OH O • point defects - from molecular water (e.g. at the surface). The results underscore the reliability of LIBS for the quantification of bulk protons in perovskite-type oxides, positioning it as a valuable alternative to conventional methods. • Reliable proton quantification in BFY via LIBS without defect knowledge. • FT-IR confirms absence of surface water, ensuring bulk water signal. • Oxygen pump decouples water uptake and oxygen exchange in reducing BFY.

Authors

Institutions

Publication Details

Journal
Solid State Ionics
Published
2025-10-15
DOI
https://doi.org/10.1016/j.ssi.2025.117033
Primary Topic
Advancements in Solid Oxide Fuel Cells
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Quantifying protons in triple conducting perovskite-type oxides via laser-induced breakdown spectroscopy – A comparative validation approach

Andreas Limbeck, Matthias Weil, Alexander Karl Opitz, Maximilian Weiß et al.
Solid State Ionics
Advancements in Solid Oxide Fuel Cells
article

Quantifying protons in triple conducting perovskite-type oxides via laser-induced breakdown spectroscopy – A comparative validation approach

Andreas Limbeck, Matthias Weil, Alexander Karl Opitz, Maximilian Weiß, M. Maurer
article en

Abstract

Proton-conducting oxides are promising materials for renewable energy technologies - e.g. as electrolytes and electrodes in solid oxide cells or membranes for hydrogen purification. Particularly relevant for these applications are perovskites, which can accommodate high concentrations of protons in their crystal structure. However, quantifying the proton concentration is challenging under reducing conditions, OH uptake and oxygen loss occur simultaneously, causing compensating weight changes. Thus, attributing weight changes directly to OH uptake is not possible without complementary techniques for validation. Here, we focus on quantifying the proton concentration in the triple conducting perovskite-type oxide BaFe 0.85 Y 0.15 O 3– δ (BFY) under various oxidation and protonation states. To do so, we introduce an alternative analytical method, which is capable of direct proton detection in perovskites and well-suited for in-situ quantification: Laser-induced breakdown spectroscopy (LIBS). This technique analyses characteristic emissions from the plasma generated by UV-laser irradiation of the material. Validation of results involved gravimetry and Fourier-transform infrared spectroscopy (FT-IR). While gravimetry was used to determine the proton concentration under special experimental conditions, FT-IR spectroscopy was used to distinguish the protons – located in the perovskite structure in the form of OH O • point defects - from molecular water (e.g. at the surface). The results underscore the reliability of LIBS for the quantification of bulk protons in perovskite-type oxides, positioning it as a valuable alternative to conventional methods. • Reliable proton quantification in BFY via LIBS without defect knowledge. • FT-IR confirms absence of surface water, ensuring bulk water signal. • Oxygen pump decouples water uptake and oxygen exchange in reducing BFY.

Solid State IonicsVol. 432
TU Wien (AT)
Openalex Percentile: Top 77%
Advancements in Solid Oxide Fuel Cells
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.