Inversion of tunnel fires using limited monitored temperature data based on transfer learning approach and full-scale scenario applications

Numerical simulation coupled with deep learning models has proven effective for inversing fire source parameters in tunnel fires. However, models trained exclusively on numerical simulation data often struggle to adapt to diverse tunnel scenarios due to variations in tunnel geometry, sensor placement, and fluctuating heat release rate (HRR). To address these challenges, this study proposes a novel transfer learning framework. The model is pre-trained on numerical simulation datasets and uses temperature data from a limited number of sensors beneath the tunnel ceiling to inverse fire location and real-time HRR. The results demonstrate that the model achieves high accuracy using only six temperature sensors, even when positioned far from the fire source, achieving Coefficient of determination (R 2 ) values exceeding 0.99. Full model fine-tuning enhances the model's adaptability to variations in tunnel geometry, demonstrating remarkable performance in reduced-scale fire tests with R 2 values above 0.99 for fire location and 0.86 for HRR. The method is further validated in full-scale tunnel fires with highly variable HRR patterns. To handle sensor damage or data loss, the model utilizes temperature data from sensors farther from the fire source, maintaining R 2 values above 0.99 for fire location and 0.82 for HRR in the test set. Additionally, the model performs well in inversing HRR during the growth and stable periods of fires in both reduced-scale and full-scale tunnels, achieving Mean Absolute Percentage Error (MAPE) values below 0.2. This capability is critical for early fire detection and effective emergency response in real tunnel fire scenarios. • A transfer learning method proposed for tunnel fire inversion with sparse sensors. • Integrated fire test and simulation data to enhance cross-scale generalization. • Validated on full-scale tunnel fire tests under varied sensor availability. • Achieved fire inversion across growth, stable, and decay fire periods.

Authors

Publication Details

Journal
Engineering Applications of Artificial Intelligence
Published
2025-10-15
DOI
https://doi.org/10.1016/j.engappai.2025.112708
Citations
3
Primary Topic
Fire Detection and Safety Systems
Type
article
Field-Weighted Citation Impact
3.91
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Inversion of tunnel fires using limited monitored temperature data based on transfer learning approach and full-scale scenario applications

Xin Guo, Dong Yang, Li Jiang, Ying Yang
3 citations
Engineering Applications of Artificial Intelligence
Fire Detection and Safety Systems
3.91
article

Inversion of tunnel fires using limited monitored temperature data based on transfer learning approach and full-scale scenario applications

Xin Guo, Dong Yang, Li Jiang, Ying Yang
article en
3 citations

Abstract

Numerical simulation coupled with deep learning models has proven effective for inversing fire source parameters in tunnel fires. However, models trained exclusively on numerical simulation data often struggle to adapt to diverse tunnel scenarios due to variations in tunnel geometry, sensor placement, and fluctuating heat release rate (HRR). To address these challenges, this study proposes a novel transfer learning framework. The model is pre-trained on numerical simulation datasets and uses temperature data from a limited number of sensors beneath the tunnel ceiling to inverse fire location and real-time HRR. The results demonstrate that the model achieves high accuracy using only six temperature sensors, even when positioned far from the fire source, achieving Coefficient of determination (R 2 ) values exceeding 0.99. Full model fine-tuning enhances the model's adaptability to variations in tunnel geometry, demonstrating remarkable performance in reduced-scale fire tests with R 2 values above 0.99 for fire location and 0.86 for HRR. The method is further validated in full-scale tunnel fires with highly variable HRR patterns. To handle sensor damage or data loss, the model utilizes temperature data from sensors farther from the fire source, maintaining R 2 values above 0.99 for fire location and 0.82 for HRR in the test set. Additionally, the model performs well in inversing HRR during the growth and stable periods of fires in both reduced-scale and full-scale tunnels, achieving Mean Absolute Percentage Error (MAPE) values below 0.2. This capability is critical for early fire detection and effective emergency response in real tunnel fire scenarios. • A transfer learning method proposed for tunnel fire inversion with sparse sensors. • Integrated fire test and simulation data to enhance cross-scale generalization. • Validated on full-scale tunnel fire tests under varied sensor availability. • Achieved fire inversion across growth, stable, and decay fire periods.

Engineering Applications of Artificial IntelligenceVol. 162
Openalex Percentile: Top 6%
Fire Detection and Safety Systems
3.91
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.