Calibrated Global Logit Fusion (CGLF) for Fetal Health Classification Using Cardiotocographic Data

Accurate detection of fetal distress from cardiotocography (CTG) is clinically critical but remains subjective and error-prone. In this research, we present a leakage-safe Calibrated Global Logit Fusion (CGLF) framework that couples TabNet’s sparse, attention-based feature selection with XGBoost’s gradient-boosted rules and fuses their class probabilities through global logit blending followed by per-class vector temperature calibration. Class imbalance is addressed with SMOTE–Tomek for TabNet and one XGBoost stream (XGB–A), and class-weighted training for a second stream (XGB–B). To prevent information leakage, all preprocessing, resampling, and weighting are fitted only on the training split within each outer fold. Out-of-fold (OOF) predictions from the outer-train split are then used to optimize blend weights and fit calibration parameters, which are subsequently applied once to the corresponding held-out outer-test fold. Our calibration-guided logit fusion (CGLF) matches top-tier discrimination on the public Fetal Health dataset while producing more reliable probability estimates than strong standalone baselines. Under nested cross-validation, CGLF delivers comparable AUROC and overall accuracy to the best tree-based model, with visibly improved calibration and slightly lower balanced accuracy in some splits. We also provide interpretability and overfitting checks via TabNet sparsity, feature stability analysis, and sufficiency (k95) curves. Finally, threshold tuning under a balanced-accuracy floor preserves sensitivity to pathological cases, aligning operating points with risk-aware obstetric decision support. Overall, CGLF is a calibration-centric, leakage-controlled CTG pipeline that is interpretable and suited to threshold-based clinical deployment.

Authors

Institutions

Publication Details

Journal
Electronics
Published
2025-10-13
DOI
https://doi.org/10.3390/electronics14204013
Primary Topic
Neonatal and fetal brain pathology
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Calibrated Global Logit Fusion (CGLF) for Fetal Health Classification Using Cardiotocographic Data

Juntae Kim, Mehret Ephrem Abraha
Electronics
Neonatal and fetal brain pathology
article

Calibrated Global Logit Fusion (CGLF) for Fetal Health Classification Using Cardiotocographic Data

Juntae Kim, Mehret Ephrem Abraha
article en

Abstract

Accurate detection of fetal distress from cardiotocography (CTG) is clinically critical but remains subjective and error-prone. In this research, we present a leakage-safe Calibrated Global Logit Fusion (CGLF) framework that couples TabNet’s sparse, attention-based feature selection with XGBoost’s gradient-boosted rules and fuses their class probabilities through global logit blending followed by per-class vector temperature calibration. Class imbalance is addressed with SMOTE–Tomek for TabNet and one XGBoost stream (XGB–A), and class-weighted training for a second stream (XGB–B). To prevent information leakage, all preprocessing, resampling, and weighting are fitted only on the training split within each outer fold. Out-of-fold (OOF) predictions from the outer-train split are then used to optimize blend weights and fit calibration parameters, which are subsequently applied once to the corresponding held-out outer-test fold. Our calibration-guided logit fusion (CGLF) matches top-tier discrimination on the public Fetal Health dataset while producing more reliable probability estimates than strong standalone baselines. Under nested cross-validation, CGLF delivers comparable AUROC and overall accuracy to the best tree-based model, with visibly improved calibration and slightly lower balanced accuracy in some splits. We also provide interpretability and overfitting checks via TabNet sparsity, feature stability analysis, and sufficiency (k95) curves. Finally, threshold tuning under a balanced-accuracy floor preserves sensitivity to pathological cases, aligning operating points with risk-aware obstetric decision support. Overall, CGLF is a calibration-centric, leakage-controlled CTG pipeline that is interpretable and suited to threshold-based clinical deployment.

ElectronicsVol. 14(20)
Dongguk University (KR)
National Research Foundation, National Research Foundation of Korea, Iran Telecommunication Research Center, Ministry of Science and ICT, South Korea, Institute for Information and Communications Technology Promotion
Openalex Percentile: Top 58%
Neonatal and fetal brain pathology
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.