Rapid On-Demand Point-of-Care Monitoring of Clozapine and Its Metabolite Norclozapine Using Miniature Mass Spectrometry

<b>Background/Objectives</b>: Clozapine remains the gold standard for treatment-resistant schizophrenia. However, its narrow therapeutic window and risk of severe side effects require close monitoring of both clozapine and its primary metabolite, norclozapine. Existing therapeutic drug monitoring (TDM) methods are limited by delays, high costs, and operational complexity. This study introduces three rapid point-of-care (POC) assays utilizing a miniature mass spectrometer (Mini-MS) to quantify clozapine and norclozapine in plasma, whole blood, and dried blood spots (DBSs), facilitating applications across diverse clinical settings. <b>Methods</b>: The analytical performance of the assay was evaluated for sensitivity, specificity, reproducibility, and correlation with reference methods. Clinical samples from two hospitals were analysed and validated against conventional liquid chromatography tandem mass spectrometry (LC-MS/MS) reference standards at New South Wales Health Pathology (NSWHP) and Tsinghua University laboratories. <b>Results</b>: The Mini-MS assay accurately quantified both analytes within therapeutic ranges across all matrices. Inter-assay coefficients of variation ranged from 7.9 to 14.1% for clozapine and from 1.6 to 14.6% for norclozapine. Accuracy fell between 85 and 117% in plasma and blood extracts. Strong linearity was demonstrated (R<sup>2</sup> = 0.98-0.99) over the concentration range of 10-1000 ng/mL. Results from the Mini-MS analysis showed excellent correlations with LC-MS/MS results (r = 0.998). <b>Conclusions</b>: In this proof-of-concept study, the Mini-MS-based POC assays enable rapid, reliable quantification of clozapine and norclozapine, with performance comparable to conventional laboratory methods. This platform supports real-time TDM, facilitating timely dose adjustments, adherence monitoring, and ultimately improving patient outcomes.

Authors

Institutions

Publication Details

Journal
Pharmaceuticals
Published
2025-10-14
DOI
https://doi.org/10.3390/ph18101549
Citations
1
Primary Topic
Forensic Toxicology and Drug Analysis
Type
article
Field-Weighted Citation Impact
1.31

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Rapid On-Demand Point-of-Care Monitoring of Clozapine and Its Metabolite Norclozapine Using Miniature Mass Spectrometry

John O’Sullivan, Michael Fitzpatrick, Yuzhong Zheng, Jiexun Bu et al.
1 citations
Pharmaceuticals
Forensic Toxicology and Drug Analysis
1.31
article

Rapid On-Demand Point-of-Care Monitoring of Clozapine and Its Metabolite Norclozapine Using Miniature Mass Spectrometry

John O’Sullivan, Michael Fitzpatrick, Yuzhong Zheng, Jiexun Bu, Zhentao Li, Paul Bonnitcha, DAVID R. SULLIVAN, Xiaosuo Wang, Nan Zhang, Wenpeng Zhang, Yang Yang, Willard Lew
article en
1 citations

Abstract

<b>Background/Objectives</b>: Clozapine remains the gold standard for treatment-resistant schizophrenia. However, its narrow therapeutic window and risk of severe side effects require close monitoring of both clozapine and its primary metabolite, norclozapine. Existing therapeutic drug monitoring (TDM) methods are limited by delays, high costs, and operational complexity. This study introduces three rapid point-of-care (POC) assays utilizing a miniature mass spectrometer (Mini-MS) to quantify clozapine and norclozapine in plasma, whole blood, and dried blood spots (DBSs), facilitating applications across diverse clinical settings. <b>Methods</b>: The analytical performance of the assay was evaluated for sensitivity, specificity, reproducibility, and correlation with reference methods. Clinical samples from two hospitals were analysed and validated against conventional liquid chromatography tandem mass spectrometry (LC-MS/MS) reference standards at New South Wales Health Pathology (NSWHP) and Tsinghua University laboratories. <b>Results</b>: The Mini-MS assay accurately quantified both analytes within therapeutic ranges across all matrices. Inter-assay coefficients of variation ranged from 7.9 to 14.1% for clozapine and from 1.6 to 14.6% for norclozapine. Accuracy fell between 85 and 117% in plasma and blood extracts. Strong linearity was demonstrated (R<sup>2</sup> = 0.98-0.99) over the concentration range of 10-1000 ng/mL. Results from the Mini-MS analysis showed excellent correlations with LC-MS/MS results (r = 0.998). <b>Conclusions</b>: In this proof-of-concept study, the Mini-MS-based POC assays enable rapid, reliable quantification of clozapine and norclozapine, with performance comparable to conventional laboratory methods. This platform supports real-time TDM, facilitating timely dose adjustments, adherence monitoring, and ultimately improving patient outcomes.

PharmaceuticalsVol. 18(10)
The University of Sydney (AU), Nanchang University (CN), Royal Prince Alfred Hospital (AU), MoTeC (Australia) (AU), Bruker (China) (CN), Sydney Local Health District (AU), CM Hospital (KR), First Affiliated Hospital of Nanchang University (CN), Tsinghua University (CN)
NSW Health Pathology
Openalex Percentile: Top 18%
Forensic Toxicology and Drug Analysis
1.31
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.