Impact of the Different Corneal Storage Flasks on Endothelial Cell Loss During Cultivation—A Retrospective Analysis

<b>Objectives:</b> To evaluate the impact of different corneal storage containers-with and without corneal holders-on endothelial cell density (ECD) and endothelial cell loss (ECL) during organ culture, following a temporary shortage of Böhnke Donor Corneal Holders at a German eye bank. <b>Methods:</b> A retrospective analysis was conducted on 383 human donor corneas cultured in six types of containers between January and September 2024 at the Eye Bank of Rhineland-Palatinate. ECD was measured at 6.0 ± 1.2 days (ECD1) and again at 14.9 ± 4.4 days (ECD2) after retrieval using standardized organ culture protocols with an inverted light microscope. Group 1 (G1) used the standard 50 mL Corning<sup>®</sup> flask with the Böhnke corneal holder. Groups 2-6 used alternative containers, with or without corneal holders. ECL was defined as the difference between ECD2 and ECD1. <b>Results:</b> Mean overall ECD1 was 2478.3 ± 843.4 cells/mm<sup>2</sup>. G1 showed ECD1 < 2000 cells/mm<sup>2</sup> in 29% of corneas and low ECL (-1%). The 60 mL Ratiolab<sup>®</sup> flask with Cornea-Claw<sup>®</sup> was the best alternative, showing the lowest incidence of ECD1 < 2000 cells/mm<sup>2</sup> (7%) and no ECL. Containers without corneal holders, particularly the 100 mL Sterilin™ and 15 mL Cryogenic Tube<sup>®</sup>, had significantly higher rates of ECD1 < 2000 (40% and 75%) and greater ECL (9% and 14%). <b>Conclusions:</b> Container design, especially volume and the presence of corneal holders, significantly influences endothelial preservation. Especially a lack of corneal holders led to unacceptable endothelial cell loss. Eye banks should prioritize appropriate flask configurations to minimize tissue deterioration, particularly during supply shortages.

Authors

Institutions

Publication Details

Journal
Journal of Clinical Medicine
Published
2025-10-11
DOI
https://doi.org/10.3390/jcm14207165
Primary Topic
Corneal surgery and disorders
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Impact of the Different Corneal Storage Flasks on Endothelial Cell Loss During Cultivation—A Retrospective Analysis

Melissa Apel, Joanna Wasielica‐Poslednik, Tarek Safi, Carolin Kolb et al.
Journal of Clinical Medicine
Corneal surgery and disorders
article

Impact of the Different Corneal Storage Flasks on Endothelial Cell Loss During Cultivation—A Retrospective Analysis

Melissa Apel, Joanna Wasielica‐Poslednik, Tarek Safi, Carolin Kolb, Stephanie D. Grabitz
article en

Abstract

<b>Objectives:</b> To evaluate the impact of different corneal storage containers-with and without corneal holders-on endothelial cell density (ECD) and endothelial cell loss (ECL) during organ culture, following a temporary shortage of Böhnke Donor Corneal Holders at a German eye bank. <b>Methods:</b> A retrospective analysis was conducted on 383 human donor corneas cultured in six types of containers between January and September 2024 at the Eye Bank of Rhineland-Palatinate. ECD was measured at 6.0 ± 1.2 days (ECD1) and again at 14.9 ± 4.4 days (ECD2) after retrieval using standardized organ culture protocols with an inverted light microscope. Group 1 (G1) used the standard 50 mL Corning<sup>®</sup> flask with the Böhnke corneal holder. Groups 2-6 used alternative containers, with or without corneal holders. ECL was defined as the difference between ECD2 and ECD1. <b>Results:</b> Mean overall ECD1 was 2478.3 ± 843.4 cells/mm<sup>2</sup>. G1 showed ECD1 < 2000 cells/mm<sup>2</sup> in 29% of corneas and low ECL (-1%). The 60 mL Ratiolab<sup>®</sup> flask with Cornea-Claw<sup>®</sup> was the best alternative, showing the lowest incidence of ECD1 < 2000 cells/mm<sup>2</sup> (7%) and no ECL. Containers without corneal holders, particularly the 100 mL Sterilin™ and 15 mL Cryogenic Tube<sup>®</sup>, had significantly higher rates of ECD1 < 2000 (40% and 75%) and greater ECL (9% and 14%). <b>Conclusions:</b> Container design, especially volume and the presence of corneal holders, significantly influences endothelial preservation. Especially a lack of corneal holders led to unacceptable endothelial cell loss. Eye banks should prioritize appropriate flask configurations to minimize tissue deterioration, particularly during supply shortages.

Journal of Clinical MedicineVol. 14(20)
Johannes Gutenberg University Mainz (DE), University Medical Center of the Johannes Gutenberg University Mainz (DE)
Openalex Percentile: Top 57%
Corneal surgery and disorders
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.