Development and Comparative Evaluation of Two Enzyme-Based Amperometric Biosensor Designs for Alanine Aminotransferase Determination in Biological Fluids

Alanine aminotransferase (ALT) is a key biomarker of liver function. Compared with conventional assays for ALT detection-which are expensive, time-consuming, labor-intensive, and require experienced personnel-biosensors represent a promising alternative, but it remains unclear which biorecognitive enzymatic configuration offers the best analytical performance for ALT detection. This study presents the development and comparative evaluation of two amperometric biosensors based on oxidase biorecognition elements: pyruvate oxidase (POx) and glutamate oxidase (GlOx). Enzymes were immobilized onto platinum electrodes under optimized conditions using entrapment for POx (pH 7.4, enzyme loading 1.62 U/µL, PVA-SbQ concentration 13.2%) and covalent crosslinking for GlOx (pH 6.5, enzyme loading 2.67%, glutaraldehyde concentration 0.3%). Analytical parameters were systematically assessed, including linear range (1-500 U/L for POx vs. 5-500 U/L for GlOx), limit of detection (1 U/L for both), and sensitivity (0.75 vs. 0.49 nA/min at 100 U/L). The POx-based biosensor demonstrated higher sensitivity and lower detection limits, whereas the GlOx-based biosensor exhibited greater stability in complex solutions and reduced assay costs due to a simpler working solution. Moreover, while the POx-based system is uniquely suited for ALT determination, the GlOx-based sensor can be affected by AST activity in samples but may also be adapted for targeted AST detection. Overall, the study highlights a trade-off between sensitivity, robustness, and versatility in ALT biosensor design, providing guidance for the rational development of clinically relevant devices.

Authors

Institutions

Publication Details

Journal
Micromachines
Published
2025-10-15
DOI
https://doi.org/10.3390/mi16101168
Primary Topic
Amino Acid Enzymes and Metabolism
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Development and Comparative Evaluation of Two Enzyme-Based Amperometric Biosensor Designs for Alanine Aminotransferase Determination in Biological Fluids

О. О. Солдаткін, Daryna Mruga, V. M. Pyeshkova, S. V. Dzyadevych et al.
Micromachines
Amino Acid Enzymes and Metabolism
article

Development and Comparative Evaluation of Two Enzyme-Based Amperometric Biosensor Designs for Alanine Aminotransferase Determination in Biological Fluids

О. О. Солдаткін, Daryna Mruga, V. M. Pyeshkova, S. V. Dzyadevych, V. A. Bakhmat, Yevhen Vakhovskyі
article en

Abstract

Alanine aminotransferase (ALT) is a key biomarker of liver function. Compared with conventional assays for ALT detection-which are expensive, time-consuming, labor-intensive, and require experienced personnel-biosensors represent a promising alternative, but it remains unclear which biorecognitive enzymatic configuration offers the best analytical performance for ALT detection. This study presents the development and comparative evaluation of two amperometric biosensors based on oxidase biorecognition elements: pyruvate oxidase (POx) and glutamate oxidase (GlOx). Enzymes were immobilized onto platinum electrodes under optimized conditions using entrapment for POx (pH 7.4, enzyme loading 1.62 U/µL, PVA-SbQ concentration 13.2%) and covalent crosslinking for GlOx (pH 6.5, enzyme loading 2.67%, glutaraldehyde concentration 0.3%). Analytical parameters were systematically assessed, including linear range (1-500 U/L for POx vs. 5-500 U/L for GlOx), limit of detection (1 U/L for both), and sensitivity (0.75 vs. 0.49 nA/min at 100 U/L). The POx-based biosensor demonstrated higher sensitivity and lower detection limits, whereas the GlOx-based biosensor exhibited greater stability in complex solutions and reduced assay costs due to a simpler working solution. Moreover, while the POx-based system is uniquely suited for ALT determination, the GlOx-based sensor can be affected by AST activity in samples but may also be adapted for targeted AST detection. Overall, the study highlights a trade-off between sensitivity, robustness, and versatility in ALT biosensor design, providing guidance for the rational development of clinically relevant devices.

MicromachinesVol. 16(10)
Taras Shevchenko National University of Kyiv (UA), National Technical University of Ukraine “Igor Sikorsky Kyiv Polytechnic Institute” (UA), University of Warwick (GB), Institute of Molecular Biology and Genetics (UA)
Science Foundation Ireland
Openalex Percentile: Top 72%
Amino Acid Enzymes and Metabolism
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.