Stretch-responsive triboelectric nanogenerator based on conductive PVA/AC hydrogel for human activity monitoring

• This study introduces a skin-integrated, flexible, and stretchable self-powered flexion sensor utilizing a stretch-responsive triboelectric nanogenerator (SR-TENG) for monitoring human motion. • The proposed device is fabricated using a conductive Poly (Vinyl Alcohol)/Activated Carbon hydrogel electrode, enabling efficient energy harvesting and real-time motion detection. • Systematic studies on the surface and microstructures of the stretchable SR-TENG reveal that optimizing the surface roughness of Ecoflex triboelectric layers and the porosity of the PVA/AC hydrogel electrode significantly enhances electrostatic induction and improves electrical output performance. • The mechanical stability and stretchability of the proposed SR-TENG were evaluated using a universal tensile testing machine, ensuring its durability and performance under mechanical deformation. • These assessments confirm the device's reliability for applications in wearable energy harvesting and human motion monitoring. Flexible and stretchable triboelectric nanogenerators (TENGs) are promising energy harvesters and tactile sensors capable of capturing and converting mechanical energy from daily activities into electrical signals. Their ability to function as self-powered devices makes them ideal for various applications, including wearable electronics and interactive sensing technologies. This study introduces a skin-integrated, flexible, and stretchable self-powered flexion sensor utilizing a stretch-responsive triboelectric nanogenerator (SR-TENG) for monitoring human motion. The proposed device is fabricated using a conductive poly (vinyl alcohol)/activated carbon hydrogel electrode, enabling efficient energy harvesting and real-time motion detection. The developed SR-TENG demonstrates the potential for wearable sensing applications, offering a reliable and sustainable solution for human activity monitoring. Systematic studies on the surface and microstructures of the stretchable SR-TENG reveal that optimizing the surface roughness of Ecoflex triboelectric layer and the porosity of the PVA/AC hydrogel electrode significantly enhances electrostatic induction and improves electrical output performance. As a result, the SR-TENG generates a maximum instantaneous voltage of 69 V and a peak instantaneous power density of 11.40 µW/cm 2 , demonstrating its potential for efficient self-powered applications. The mechanical stability and stretchability of the proposed SR-TENG were evaluated using a universal tensile testing machine, ensuring its durability and performance under mechanical deformation. These assessments confirm the device's reliability for applications in wearable energy harvesting and human motion monitoring. The SR-TENG, demonstrated as a simple skin-attachable patch, effectively monitors physiological signals such as muscle movement; this showcases its potential for sensing and energy generation, emphasizing its applicability in wearable health monitoring systems.

Authors

Institutions

Publication Details

Journal
Results in Engineering
Published
2025-10-15
DOI
https://doi.org/10.1016/j.rineng.2025.107734
Citations
2
Primary Topic
Advanced Sensor and Energy Harvesting Materials
Type
article
Field-Weighted Citation Impact
1.35
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Stretch-responsive triboelectric nanogenerator based on conductive PVA/AC hydrogel for human activity monitoring

Pramila Viswanathan, Arunkumar Chandrasekhar
2 citations
Results in Engineering
Advanced Sensor and Energy Harvesting Materials
1.35
article

Stretch-responsive triboelectric nanogenerator based on conductive PVA/AC hydrogel for human activity monitoring

Pramila Viswanathan, Arunkumar Chandrasekhar
article en
2 citations

Abstract

• This study introduces a skin-integrated, flexible, and stretchable self-powered flexion sensor utilizing a stretch-responsive triboelectric nanogenerator (SR-TENG) for monitoring human motion. • The proposed device is fabricated using a conductive Poly (Vinyl Alcohol)/Activated Carbon hydrogel electrode, enabling efficient energy harvesting and real-time motion detection. • Systematic studies on the surface and microstructures of the stretchable SR-TENG reveal that optimizing the surface roughness of Ecoflex triboelectric layers and the porosity of the PVA/AC hydrogel electrode significantly enhances electrostatic induction and improves electrical output performance. • The mechanical stability and stretchability of the proposed SR-TENG were evaluated using a universal tensile testing machine, ensuring its durability and performance under mechanical deformation. • These assessments confirm the device's reliability for applications in wearable energy harvesting and human motion monitoring. Flexible and stretchable triboelectric nanogenerators (TENGs) are promising energy harvesters and tactile sensors capable of capturing and converting mechanical energy from daily activities into electrical signals. Their ability to function as self-powered devices makes them ideal for various applications, including wearable electronics and interactive sensing technologies. This study introduces a skin-integrated, flexible, and stretchable self-powered flexion sensor utilizing a stretch-responsive triboelectric nanogenerator (SR-TENG) for monitoring human motion. The proposed device is fabricated using a conductive poly (vinyl alcohol)/activated carbon hydrogel electrode, enabling efficient energy harvesting and real-time motion detection. The developed SR-TENG demonstrates the potential for wearable sensing applications, offering a reliable and sustainable solution for human activity monitoring. Systematic studies on the surface and microstructures of the stretchable SR-TENG reveal that optimizing the surface roughness of Ecoflex triboelectric layer and the porosity of the PVA/AC hydrogel electrode significantly enhances electrostatic induction and improves electrical output performance. As a result, the SR-TENG generates a maximum instantaneous voltage of 69 V and a peak instantaneous power density of 11.40 µW/cm 2 , demonstrating its potential for efficient self-powered applications. The mechanical stability and stretchability of the proposed SR-TENG were evaluated using a universal tensile testing machine, ensuring its durability and performance under mechanical deformation. These assessments confirm the device's reliability for applications in wearable energy harvesting and human motion monitoring. The SR-TENG, demonstrated as a simple skin-attachable patch, effectively monitors physiological signals such as muscle movement; this showcases its potential for sensing and energy generation, emphasizing its applicability in wearable health monitoring systems.

Results in EngineeringVol. 28
Vellore Institute of Technology University (IN)
Openalex Percentile: Top 17%
Advanced Sensor and Energy Harvesting Materials
1.35
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.