Ultrasound Assessment of Breech Engagement: Breech Progression Angle and Prediction of External Cephalic Version Success

<b>Objectives</b>: To evaluate the role of breech progression angle (BPA), a novel transperineal ultrasound parameter, as a predictor of external cephalic version (ECV) success, and to compare BPA between breech and transverse lie presentations. <b>Methods</b>: This prospective exploratory study was nested within a randomized clinical trial (NCT06449430) at Virgen de la Arrixaca University Hospital, Murcia, Spain. Eligible participants were pregnant women ≥18 years with a singleton fetus in non-cephalic presentation at term, without contraindications to vaginal birth. BPA was measured transperineally following standardized methodology prior to ECV, performed under either spinal analgesia or propofol sedation. Logistic regression models adjusted for maternal and obstetric variables assessed the association between BPA and ECV success. Receiver operating characteristic (ROC) curves were generated to evaluate predictive accuracy. <b>Results</b>: A total of 117 women were included: 100 with breech and 17 with transverse lie presentations. Median BPA was significantly higher in breech compared with transverse lie (87.2° vs. 70.2°, <i>p</i> < 0.001). In the overall cohort, BPA was not significantly associated with ECV success (OR 0.97, 95% CI 0.94-1.00; <i>p</i> = 0.068). However, in breech presentations, BPA was independently associated with ECV success (adjusted OR 0.95, 95% CI 0.91-0.99; <i>p</i> = 0.015). The area under the ROC curve for BPA predicting ECV success in breech cases was 0.64 (95% CI 0.53-0.73). Predictive accuracy was poor for transverse lie (AUC 0.27, 95% CI 0.08-0.56). <b>Conclusions</b>: BPA measured by transperineal ultrasound does not provide clinically useful information for predicting the success of external cephalic version, either in breech or transverse lie.

Authors

Institutions

Publication Details

Journal
Journal of Clinical Medicine
Published
2025-10-11
DOI
https://doi.org/10.3390/jcm14207179
Primary Topic
Maternal and Perinatal Health Interventions
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Ultrasound Assessment of Breech Engagement: Breech Progression Angle and Prediction of External Cephalic Version Success

Rosa María Gallego-Pozuelo, Aníbal Nieto Díaz, C. de Paco Matallana, José Eliseo Blanco‐Carnero et al.
Journal of Clinical Medicine
Maternal and Perinatal Health Interventions
article

Ultrasound Assessment of Breech Engagement: Breech Progression Angle and Prediction of External Cephalic Version Success

Rosa María Gallego-Pozuelo, Aníbal Nieto Díaz, C. de Paco Matallana, José Eliseo Blanco‐Carnero, Javier Sánchez‐Romero, Fernando Araico‐Rodríguez, Cristina Ortuño-Hernández, Ana Martínez-Zarco, Rocío Barroso-Linares
article en

Abstract

<b>Objectives</b>: To evaluate the role of breech progression angle (BPA), a novel transperineal ultrasound parameter, as a predictor of external cephalic version (ECV) success, and to compare BPA between breech and transverse lie presentations. <b>Methods</b>: This prospective exploratory study was nested within a randomized clinical trial (NCT06449430) at Virgen de la Arrixaca University Hospital, Murcia, Spain. Eligible participants were pregnant women ≥18 years with a singleton fetus in non-cephalic presentation at term, without contraindications to vaginal birth. BPA was measured transperineally following standardized methodology prior to ECV, performed under either spinal analgesia or propofol sedation. Logistic regression models adjusted for maternal and obstetric variables assessed the association between BPA and ECV success. Receiver operating characteristic (ROC) curves were generated to evaluate predictive accuracy. <b>Results</b>: A total of 117 women were included: 100 with breech and 17 with transverse lie presentations. Median BPA was significantly higher in breech compared with transverse lie (87.2° vs. 70.2°, <i>p</i> < 0.001). In the overall cohort, BPA was not significantly associated with ECV success (OR 0.97, 95% CI 0.94-1.00; <i>p</i> = 0.068). However, in breech presentations, BPA was independently associated with ECV success (adjusted OR 0.95, 95% CI 0.91-0.99; <i>p</i> = 0.015). The area under the ROC curve for BPA predicting ECV success in breech cases was 0.64 (95% CI 0.53-0.73). Predictive accuracy was poor for transverse lie (AUC 0.27, 95% CI 0.08-0.56). <b>Conclusions</b>: BPA measured by transperineal ultrasound does not provide clinically useful information for predicting the success of external cephalic version, either in breech or transverse lie.

Journal of Clinical MedicineVol. 14(20)
Instituto Murciano de Investigación Biosanitaria (ES), Hospital Universitario Virgen de la Arrixaca (ES), Universidad de Murcia (ES)
Openalex Percentile: Top 64%
Maternal and Perinatal Health Interventions
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.