Deep learning optimized dual-analyte detection-based biosensor for monitoring pregnancy stage using a urine sample

This study presents a hybrid deep learning (DL) approach for designing and optimizing a photonic crystal fiber (PCF)-based surface plasmon resonance (SPR) multi-analyte biosensor. Using a simulation based on the finite element method (FEM), we generated a comprehensive data set that captures various sensor parameters and refractive index (RI) values. A hybrid recurrent neural network long-short-term memory (RNN-LSTM) model was developed to predict confinement loss (CL), which showed superior performance with an MSE of 0.0014, an MAE of 0.0188, and an R<sup>2</sup> of 0.9510 compared to other DL and machine learning (ML) models. The proposed model shows a maximum amplitude sensitivity (AS) of 3102.41 RIU<sup>-1</sup>, a wavelength sensitivity (WS) of 10,000 nm/RIU, and a sensor resolution (SR) of 1 × 10<sup>-5</sup>. The effectiveness of the model was validated through extensive analysis, including ablation studies and SHAP-based explainability analysis. Our findings highlight the potential of DL to improve multi-analyte biosensor design and performance prediction.

Authors

Institutions

Publication Details

Journal
Biomedical Optics Express
Published
2025-10-15
DOI
https://doi.org/10.1364/boe.580226
Citations
1
Primary Topic
Artificial Intelligence in Healthcare
Type
article
Field-Weighted Citation Impact
2.94
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Deep learning optimized dual-analyte detection-based biosensor for monitoring pregnancy stage using a urine sample

Kawsar Ahmed, Md. Mamun Ali, Francis M. Bui, Li Chen et al.
1 citations
Biomedical Optics Express
Artificial Intelligence in Healthcare
2.94
article

Deep learning optimized dual-analyte detection-based biosensor for monitoring pregnancy stage using a urine sample

Kawsar Ahmed, Md. Mamun Ali, Francis M. Bui, Li Chen, Santosh Kumar, Md. Shohidullah
article en
1 citations

Abstract

This study presents a hybrid deep learning (DL) approach for designing and optimizing a photonic crystal fiber (PCF)-based surface plasmon resonance (SPR) multi-analyte biosensor. Using a simulation based on the finite element method (FEM), we generated a comprehensive data set that captures various sensor parameters and refractive index (RI) values. A hybrid recurrent neural network long-short-term memory (RNN-LSTM) model was developed to predict confinement loss (CL), which showed superior performance with an MSE of 0.0014, an MAE of 0.0188, and an R<sup>2</sup> of 0.9510 compared to other DL and machine learning (ML) models. The proposed model shows a maximum amplitude sensitivity (AS) of 3102.41 RIU<sup>-1</sup>, a wavelength sensitivity (WS) of 10,000 nm/RIU, and a sensor resolution (SR) of 1 × 10<sup>-5</sup>. The effectiveness of the model was validated through extensive analysis, including ablation studies and SHAP-based explainability analysis. Our findings highlight the potential of DL to improve multi-analyte biosensor design and performance prediction.

Biomedical Optics ExpressVol. 16(11)
Ahsanullah University of Science and Technology (BD), TU Dortmund University (DE), Daffodil International University (BD), University of Saskatchewan (CA), Ahmedabad University (IN), Koneru Lakshmaiah Education Foundation (IN)
Openalex Percentile: Top 6%
Artificial Intelligence in Healthcare
2.94
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.