A fully automated rotary microfluidic platform for high-throughput multiplex detection of respiratory tract pathogens

Rapid, high-throughput, timely, multiplex diagnosis of respiratory-tract infections still relies on laboratory infrastructure, sequential assays, and trained personnel, thereby delaying targeted therapy and outbreak containment. In this study, a Fully Automated rotary microfluidic platform (FA-RMP) for high-throughput multiplex respiratory tract pathogens detection was presented. FA-RMP enables a true "sample-in, result-out" workflow through the integration of swab lysis, reagent partitioning, lyophilized reverse transcription loop-mediated isothermal amplification (RT-LAMP), and moving-probe fluorescence read-out, all encapsulated with a disposable microfluidic cartridge and paired with a 9 kg, four-channel benchtop reader. The FA-RMP enables parallel processing of 16 independent reactions within 30 min, supporting simultaneous detection of up to 4 distinct clinical samples. Analytical validation using serially diluted Mycoplasma pneumoniae (MP) DNA established a limit of detection (LoD) of 50 copies µL<sup>-1</sup> and a log-linear correlation between threshold time and template load (R<sup>2</sup> = 0.9528). Testing with eight non-target respiratory pathogens yielded no amplification, confirming high analytical specificity. FA-RMP successfully detected the clinical samples with influenza A, influenza B, and MP, further demonstrating its robust multiplex detection capability. By integrating automated sample preparation, multiplex isothermal amplification and quantitative detection into a portable, high-throughput system, the platform delivers laboratory-grade performance at the point of care, serving as a scalable tool for routine respiratory pathogens screening and rapid epidemic response.

Authors

Institutions

Publication Details

Journal
Microsystems & Nanoengineering
Published
2025-10-15
DOI
https://doi.org/10.1038/s41378-025-01044-9
Citations
1
Primary Topic
Biosensors and Analytical Detection
Type
article
Field-Weighted Citation Impact
0.67
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A fully automated rotary microfluidic platform for high-throughput multiplex detection of respiratory tract pathogens

D Y Zhang, Xuefei Lv, Shiyong Yu, Chuanlong Li et al.
1 citations
Microsystems & Nanoengineering
Biosensors and Analytical Detection
0.67
article

A fully automated rotary microfluidic platform for high-throughput multiplex detection of respiratory tract pathogens

D Y Zhang, Xuefei Lv, Shiyong Yu, Chuanlong Li, Wenzhe Si, Anyi Li, Bin Liu, Liming Zhang, Yulin Deng, Pengwei Ren
article en
1 citations

Abstract

Rapid, high-throughput, timely, multiplex diagnosis of respiratory-tract infections still relies on laboratory infrastructure, sequential assays, and trained personnel, thereby delaying targeted therapy and outbreak containment. In this study, a Fully Automated rotary microfluidic platform (FA-RMP) for high-throughput multiplex respiratory tract pathogens detection was presented. FA-RMP enables a true "sample-in, result-out" workflow through the integration of swab lysis, reagent partitioning, lyophilized reverse transcription loop-mediated isothermal amplification (RT-LAMP), and moving-probe fluorescence read-out, all encapsulated with a disposable microfluidic cartridge and paired with a 9 kg, four-channel benchtop reader. The FA-RMP enables parallel processing of 16 independent reactions within 30 min, supporting simultaneous detection of up to 4 distinct clinical samples. Analytical validation using serially diluted Mycoplasma pneumoniae (MP) DNA established a limit of detection (LoD) of 50 copies µL<sup>-1</sup> and a log-linear correlation between threshold time and template load (R<sup>2</sup> = 0.9528). Testing with eight non-target respiratory pathogens yielded no amplification, confirming high analytical specificity. FA-RMP successfully detected the clinical samples with influenza A, influenza B, and MP, further demonstrating its robust multiplex detection capability. By integrating automated sample preparation, multiplex isothermal amplification and quantitative detection into a portable, high-throughput system, the platform delivers laboratory-grade performance at the point of care, serving as a scalable tool for routine respiratory pathogens screening and rapid epidemic response.

Microsystems & NanoengineeringVol. 11(1)
Beijing Institute of Technology (CN), Peking University (CN), Beijing Institute of Big Data Research (CN), Beijing Research Institute of Mechanical and Electrical Technology (CN), Peking University Third Hospital (CN)
Openalex Percentile: Top 26%
Biosensors and Analytical Detection
0.67
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.