A passive DCNN based Vision-to-Haptics control scheme for avoiding iatrogenic harm in robotic-assisted surgery

Robotic-Assisted Minimally Invasive Surgery (RAMIS) has gained the attention of researchers worldwide, as it minimizes the infection risk and iatrogenic harm done to the patient, due to the fact that the surgical tool enters the human body through a tiny incision. A critical issue in RAMIS is to ensure that the incision (tool entrance) is not further damaged due to excessive stress applied by the surgical tool. In this work, a vision-to-haptics control scheme for a leader-follower robotic setup is proposed, that provides the surgeon with the appropriate force/torque feedback for avoiding further stress applied to the incision, in real-time. In the core of the method, a Deep Convolutional Neural Network (DCNN) is employed that is able to identify and quantify potentially harmful situations. The proposed method is proven to be passive and it is experimentally evaluated using a leader-follower setup. The results show the reduction of the deformation of the incision hole by the tool shaft, as compared to the case in which no force-feedback was provided to the human-user.

Authors

Institutions

Publication Details

Published
2025-06-24
DOI
https://doi.org/10.23919/ecc65951.2025.11187017
Primary Topic
Teleoperation and Haptic Systems
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A passive DCNN based Vision-to-Haptics control scheme for avoiding iatrogenic harm in robotic-assisted surgery

Theodora Kastritsi, Mae Papadopoulou, Dimitrios Papageorgiou, Nikolaos Efstathopoulos
Teleoperation and Haptic Systems
article

A passive DCNN based Vision-to-Haptics control scheme for avoiding iatrogenic harm in robotic-assisted surgery

Theodora Kastritsi, Mae Papadopoulou, Dimitrios Papageorgiou, Nikolaos Efstathopoulos
article en

Abstract

Robotic-Assisted Minimally Invasive Surgery (RAMIS) has gained the attention of researchers worldwide, as it minimizes the infection risk and iatrogenic harm done to the patient, due to the fact that the surgical tool enters the human body through a tiny incision. A critical issue in RAMIS is to ensure that the incision (tool entrance) is not further damaged due to excessive stress applied by the surgical tool. In this work, a vision-to-haptics control scheme for a leader-follower robotic setup is proposed, that provides the surgeon with the appropriate force/torque feedback for avoiding further stress applied to the incision, in real-time. In the core of the method, a Deep Convolutional Neural Network (DCNN) is employed that is able to identify and quantify potentially harmful situations. The proposed method is proven to be passive and it is experimentally evaluated using a leader-follower setup. The results show the reduction of the deformation of the incision hole by the tool shaft, as compared to the case in which no force-feedback was provided to the human-user.

Mediterranean University (ME), A.P.E. Research (Italy) (IT)
Openalex Percentile: Top 70%
Teleoperation and Haptic Systems
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

A passive DCNN based Vision-to-Haptics control scheme for avoiding iatrogenic harm in robotic-assisted surgery — Theodora Kastritsi, Mae Papadopoulou, et al. · (2025) | TGRS Research Map | TGRS