Disturbance-rejection-oriented temperature control of shrink tunnels under varying grid voltage

This paper addresses the design of temperature controllers for shrink tunnels, which are machines composed of an industrial oven and a conveyor belt employed for packaging purposes. Specifically, the present work focuses on the rejection of disturbances arising from two sources: (i) the flow of products inserted into the oven by the conveyor belt, which causes abrupt temperature drops, and (ii) the varying grid voltage, which perturbs the heat generated by the heat resistors commanded by the regulator. To that end, a recent control architecture is extended with the addition of (i) feedforward compensators and (ii) a suitable rescaling strategy for the control actions, effectively addressing the previously mentioned disturbances. The performances of the proposed strategy are validated on an experimental workbench, showing improved disturbance rejection capabilities compared to the baseline approach.

Authors

Institutions

Publication Details

Published
2025-06-24
DOI
https://doi.org/10.23919/ecc65951.2025.11187036
Primary Topic
High-Voltage Power Transmission Systems
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Disturbance-rejection-oriented temperature control of shrink tunnels under varying grid voltage

Fabio Previdi, Antonio Ferramosca, Davide Previtali, Leandro Pitturelli
High-Voltage Power Transmission Systems
article

Disturbance-rejection-oriented temperature control of shrink tunnels under varying grid voltage

Fabio Previdi, Antonio Ferramosca, Davide Previtali, Leandro Pitturelli
article en

Abstract

This paper addresses the design of temperature controllers for shrink tunnels, which are machines composed of an industrial oven and a conveyor belt employed for packaging purposes. Specifically, the present work focuses on the rejection of disturbances arising from two sources: (i) the flow of products inserted into the oven by the conveyor belt, which causes abrupt temperature drops, and (ii) the varying grid voltage, which perturbs the heat generated by the heat resistors commanded by the regulator. To that end, a recent control architecture is extended with the addition of (i) feedforward compensators and (ii) a suitable rescaling strategy for the control actions, effectively addressing the previously mentioned disturbances. The performances of the proposed strategy are validated on an experimental workbench, showing improved disturbance rejection capabilities compared to the baseline approach.

University of Bergamo (IT)
Openalex Percentile: Top 71%
High-Voltage Power Transmission Systems
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Disturbance-rejection-oriented temperature control of shrink tunnels under varying grid voltage — Fabio Previdi, Antonio Ferramosca, et al. · (2025) | TGRS Research Map | TGRS