Study of Transient Earth Voltage Sensor with Additional Plate

Air insulated switchgear is one of the critical equipment in modern distribution systems. Being a key unit in high voltage (HV) electrical systems in various ranges of voltages, makes switchgears vulnerable to phenomenon known as partial discharge (PD). According to statistics for past decades PD caused almost 40% of all failures and shortages in electrical systems. PD is tending to progress by time, accelerating the aging rate of insulating materials causing reduced insulation parameters, leading to inevitable breakdown of insulation layers. Implementation of the Transient Earth Voltage (TEV) sensors are common methods of locating the PD signals. However, in some cases TEV sensors might lack sensitivity in comparison with other conventional methods. This paper will focus on providing information about (TEV) sensor assembly process, propose TEV sensor of alternative design that offer higher sensitivity and its frequency response analysis. This paper also will contribute the TEV sensor design for future research to provide comparative analysis.

Authors

Institutions

Publication Details

Published
2025-08-15
DOI
https://doi.org/10.1109/etee66180.2025.11192919
Primary Topic
Geophysics and Sensor Technology
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Study of Transient Earth Voltage Sensor with Additional Plate

Azer Muslumzade, Sahib Ibrahimkhalilov, Chingiz Gurbanov
Geophysics and Sensor Technology
article

Study of Transient Earth Voltage Sensor with Additional Plate

Azer Muslumzade, Sahib Ibrahimkhalilov, Chingiz Gurbanov
article en

Abstract

Air insulated switchgear is one of the critical equipment in modern distribution systems. Being a key unit in high voltage (HV) electrical systems in various ranges of voltages, makes switchgears vulnerable to phenomenon known as partial discharge (PD). According to statistics for past decades PD caused almost 40% of all failures and shortages in electrical systems. PD is tending to progress by time, accelerating the aging rate of insulating materials causing reduced insulation parameters, leading to inevitable breakdown of insulation layers. Implementation of the Transient Earth Voltage (TEV) sensors are common methods of locating the PD signals. However, in some cases TEV sensors might lack sensitivity in comparison with other conventional methods. This paper will focus on providing information about (TEV) sensor assembly process, propose TEV sensor of alternative design that offer higher sensitivity and its frequency response analysis. This paper also will contribute the TEV sensor design for future research to provide comparative analysis.

Azerbaijan State Oil and Industry University (AZ)
Openalex Percentile: Top 64%
Geophysics and Sensor Technology
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.