Research on plug-and-play scheme of relay protection device in substation

Relay protection devices are key equipment to ensure the safe and stable operation of power systems. The current design schemes of device and panel have some problems such as long power outages, heavy workload, and potential safety hazard of wiring during the transformation process, which are in sharp conflict with the requirements of safe power supply and high reliability of the power grid. Several conventional transformation schemes of the panel are presented in this paper. And a technical solution based on a new type of terminal block is proposed, aiming to achieve universal interchangeability and plug-and-play of full-voltage level protection devices, enhance power supply reliability and improve operation and maintenance convenience. It provides a method for the rapid transformation of relay protection devices.

Authors

Institutions

Publication Details

Published
2025-08-15
DOI
https://doi.org/10.1109/etee66180.2025.11193115
Primary Topic
Power Systems Fault Detection
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Research on plug-and-play scheme of relay protection device in substation

Fulai Guo, Peng Ren, Yudong Fang, Zhen Huang et al.
Power Systems Fault Detection
article

Research on plug-and-play scheme of relay protection device in substation

Fulai Guo, Peng Ren, Yudong Fang, Zhen Huang, Guangpu Zhang, Ping Zhao, Shan He, Yutao Qiu
article en

Abstract

Relay protection devices are key equipment to ensure the safe and stable operation of power systems. The current design schemes of device and panel have some problems such as long power outages, heavy workload, and potential safety hazard of wiring during the transformation process, which are in sharp conflict with the requirements of safe power supply and high reliability of the power grid. Several conventional transformation schemes of the panel are presented in this paper. And a technical solution based on a new type of terminal block is proposed, aiming to achieve universal interchangeability and plug-and-play of full-voltage level protection devices, enhance power supply reliability and improve operation and maintenance convenience. It provides a method for the rapid transformation of relay protection devices.

Wanfang Data (China) (CN), Zhejiang Energy Research Institute (CN), Shanghai Electric (China) (CN), Beijing Survey and Design Institute (China) (CN)
Openalex Percentile: Top 63%
Power Systems Fault Detection
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.