Grounding Resistance Detection Technology for Transmission Towers Based on Grounding Grid Topology Structure

In response to the measurement deviation problems caused by the difficulty of wire laying operation, inaccurate wire laying direction, and insufficient wire laying distance in the detection of grounding resistance of transmission towers, this paper proposes a non excavation grounding resistance calculation method based on accurate measurement of grounding network topology structure. By accurately measuring topological parameters such as burial depth, burial length, and distribution density of grounding grid rays, combined with dynamic correction of soil resistivity, precise calculation of grounding resistance can be achieved. To verify the effectiveness of this method, this paper selected 32 towers from the 500kV Ningxiang Xiangtan West Line and the 110kV Hegan Line for on-site testing. The results showed that the grounding resistance values calculated based on the fine topology structure of the grounding grid were in good agreement with the traditional measured values. This study provides a new technological path for detecting grounding resistance in transmission lines, which can effectively overcome the limitations of traditional detection methods and has great practical application significance.

Authors

Institutions

Publication Details

Published
2025-08-15
DOI
https://doi.org/10.1109/etee66180.2025.11192870
Primary Topic
Elevator Systems and Control
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Grounding Resistance Detection Technology for Transmission Towers Based on Grounding Grid Topology Structure

Huang Rong, Qiang Luo, G. Zhu, Wenbo Li et al.
Elevator Systems and Control
article

Grounding Resistance Detection Technology for Transmission Towers Based on Grounding Grid Topology Structure

Huang Rong, Qiang Luo, G. Zhu, Wenbo Li, Zha Yan
article en

Abstract

In response to the measurement deviation problems caused by the difficulty of wire laying operation, inaccurate wire laying direction, and insufficient wire laying distance in the detection of grounding resistance of transmission towers, this paper proposes a non excavation grounding resistance calculation method based on accurate measurement of grounding network topology structure. By accurately measuring topological parameters such as burial depth, burial length, and distribution density of grounding grid rays, combined with dynamic correction of soil resistivity, precise calculation of grounding resistance can be achieved. To verify the effectiveness of this method, this paper selected 32 towers from the 500kV Ningxiang Xiangtan West Line and the 110kV Hegan Line for on-site testing. The results showed that the grounding resistance values calculated based on the fine topology structure of the grounding grid were in good agreement with the traditional measured values. This study provides a new technological path for detecting grounding resistance in transmission lines, which can effectively overcome the limitations of traditional detection methods and has great practical application significance.

Hunan University of Science and Engineering (CN), Hunan Xiangdian Test Research Institute (China) (CN)
Openalex Percentile: Top 63%
Elevator Systems and Control
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Grounding Resistance Detection Technology for Transmission Towers Based on Grounding Grid Topology Structure — Huang Rong, Qiang Luo, et al. · (2025) | TGRS Research Map | TGRS