Probe-based metagenomic pathogen detection: advancing laboratory capacity for complex diagnosis

Probe-based pathogen enrichment, followed by NGS, is a promising tool for complex diagnosis, overcoming traditional challenges of shotgun metagenomics, namely small microbial/human genetic material ratio and demanding computational resources. Here, we assessed the combined detection performance of two Illumina probe-based panels, the Respiratory and the Urinary Pathogen ID panels (RPIP and UPIP), using 99 clinical samples of 15 different matrices (e.g., cerebrospinal fluid, plasma, serum, urine, swabs, biopsies, etc.) available from Portuguese National Reference Laboratories. This sample set involved 114 "PCR-positive hits" (Ct values range of 9.7-41.3; median of 28.4) for 52 non-redundant human pathogens. For a more detailed bioinformatics assessment, as a complement of the Illumina turnkey solution (Explify), we applied an extended version of our INSaFLU-TELEVIR(+) metagenomics pipeline. Whereas Explify analyses resulted in an initial detection frequency of 73.7% (84/114), the subsequent application of INSaFLU-TELEVIR(+), including taxonomic classification followed by confirmatory read mapping, enabled an overall detection proportion of 79.8% (91/114) of the PCR-positive hits. This translated into a detection rate increment from 54.3% (19/35) to 65.7% (23/35) for bacteria, and from 85.3% (58/68) to 89.7% (61/68) for viruses. The implemented workflow was also very satisfactory for samples with qPCR Ct values above 30, with an overall detection frequency of 71.8% (28/39) when compared with the 92.0% (46/50) observed for those with Ct ≤ 30. In summary, this study validated and established a pioneering approach at the Portuguese National Institute of Health to support clinicians in complex diagnosis, contributing to advance diagnostic capabilities toward a more informed clinical decision and potential improvement of infectious disease outcomes.

Authors

Institutions

Publication Details

Journal
Frontiers in Microbiology
Published
2025-10-14
DOI
https://doi.org/10.3389/fmicb.2025.1656831
Primary Topic
Biosensors and Analytical Detection
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Probe-based metagenomic pathogen detection: advancing laboratory capacity for complex diagnosis

Maria Paula Bajanca-Lavado, Luís Vieira, Rita Sousa, Sílvia Lopo et al.
Frontiers in Microbiology
Biosensors and Analytical Detection
article

Probe-based metagenomic pathogen detection: advancing laboratory capacity for complex diagnosis

Maria Paula Bajanca-Lavado, Luís Vieira, Rita Sousa, Sílvia Lopo, Joana Isidro, Maria João Gargaté, Rita Cordeiro, Vítor Borges, Paulo Paixão, Rita Macedo, João Paulo Gomes, Paula Palminha, Verónica Mixão, Alexandra Nunes, Miguel Pinto, Daniel Sobral, Cristina Veríssimo, Mónica Oleastro, Raquel Guiomar, Rita Ferreira, Sílvia Duarte, João Dourado Santos, Maria José Borrego, Luís Coelho
article en

Abstract

Probe-based pathogen enrichment, followed by NGS, is a promising tool for complex diagnosis, overcoming traditional challenges of shotgun metagenomics, namely small microbial/human genetic material ratio and demanding computational resources. Here, we assessed the combined detection performance of two Illumina probe-based panels, the Respiratory and the Urinary Pathogen ID panels (RPIP and UPIP), using 99 clinical samples of 15 different matrices (e.g., cerebrospinal fluid, plasma, serum, urine, swabs, biopsies, etc.) available from Portuguese National Reference Laboratories. This sample set involved 114 "PCR-positive hits" (Ct values range of 9.7-41.3; median of 28.4) for 52 non-redundant human pathogens. For a more detailed bioinformatics assessment, as a complement of the Illumina turnkey solution (Explify), we applied an extended version of our INSaFLU-TELEVIR(+) metagenomics pipeline. Whereas Explify analyses resulted in an initial detection frequency of 73.7% (84/114), the subsequent application of INSaFLU-TELEVIR(+), including taxonomic classification followed by confirmatory read mapping, enabled an overall detection proportion of 79.8% (91/114) of the PCR-positive hits. This translated into a detection rate increment from 54.3% (19/35) to 65.7% (23/35) for bacteria, and from 85.3% (58/68) to 89.7% (61/68) for viruses. The implemented workflow was also very satisfactory for samples with qPCR Ct values above 30, with an overall detection frequency of 71.8% (28/39) when compared with the 92.0% (46/50) observed for those with Ct ≤ 30. In summary, this study validated and established a pioneering approach at the Portuguese National Institute of Health to support clinicians in complex diagnosis, contributing to advance diagnostic capabilities toward a more informed clinical decision and potential improvement of infectious disease outcomes.

Frontiers in MicrobiologyVol. 16
National Institute of Health Dr. Ricardo Jorge (PT), Universidade Nova de Lisboa (PT), Universidade Lusófona (PT)
Openalex Percentile: Top 72%
Biosensors and Analytical Detection
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.