Beyond potentiometry: an amperometric approach to urea detection using antimony electrodes

In this study, we present an amperometric urea biosensor based on a custom-made antimony electrode modified with an enzymatic membrane containing immobilised urease. The biosensor showed a high sensitivity, ranging from 306.6 to 77.5 nA/mM depending on the buffer solution capacity (5–50 mM PBS). Stability tests demonstrated that the sensor retained 65% of its initial activity after 10 days at room temperature. Good repeatability was observed, with relative standard deviations below 10% for 10 replicate measurements at 0.5 mM urea. Validation with aqueous samples showed a strong correlation with a commercial colorimetric assay, with deviations not exceeding 10%. During the tests with biological samples (human saliva and serum), the biosensor reported lower urea concentrations compared with the colorimetric method, indicating that interfering compounds present in complex biological matrices can affect biosensor performance. The developed biosensor represents a simple, cost-effective and adaptable platform for urea determination, showing a strong potential for integration into point-of-care diagnostic systems.

Authors

Institutions

Publication Details

Journal
Chemija
Published
2025-10-13
DOI
https://doi.org/10.6001/chemija.2025.36.3.1
Primary Topic
Analytical Chemistry and Sensors
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Beyond potentiometry: an amperometric approach to urea detection using antimony electrodes

Justas Miškinis, Marius Butkevičius, Julija Razumienė, Marius Dagys
Chemija
Analytical Chemistry and Sensors
article

Beyond potentiometry: an amperometric approach to urea detection using antimony electrodes

Justas Miškinis, Marius Butkevičius, Julija Razumienė, Marius Dagys
article en

Abstract

In this study, we present an amperometric urea biosensor based on a custom-made antimony electrode modified with an enzymatic membrane containing immobilised urease. The biosensor showed a high sensitivity, ranging from 306.6 to 77.5 nA/mM depending on the buffer solution capacity (5–50 mM PBS). Stability tests demonstrated that the sensor retained 65% of its initial activity after 10 days at room temperature. Good repeatability was observed, with relative standard deviations below 10% for 10 replicate measurements at 0.5 mM urea. Validation with aqueous samples showed a strong correlation with a commercial colorimetric assay, with deviations not exceeding 10%. During the tests with biological samples (human saliva and serum), the biosensor reported lower urea concentrations compared with the colorimetric method, indicating that interfering compounds present in complex biological matrices can affect biosensor performance. The developed biosensor represents a simple, cost-effective and adaptable platform for urea determination, showing a strong potential for integration into point-of-care diagnostic systems.

ChemijaVol. 36(3)
Vilnius University (LT)
Openalex Percentile: Top 61%
Analytical Chemistry and Sensors
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Beyond potentiometry: an amperometric approach to urea detection using antimony electrodes — Justas Miškinis, Marius Butkevičius, et al. · Chemija (2025) | TGRS Research Map | TGRS