Are Reusable Dry Electrodes an Alternative to Gelled Electrodes for Canine Surface Electromyography?

Despite its increasing use in veterinary rehabilitation, practical constraints-such as skin preparation and single-use electrodes-limit the wider adoption of surface electromyography (sEMG). Having conventional pre-gelled Ag/AgCl electrodes as reference, we made a pioneering comparison of the performance of reusable soft polymeric dry electrodes for recording paraspinal muscle activity in dogs during treadmill walking. Twelve clinically healthy Dachshunds from both genders were evaluated under two conditions, namely: (i) dry electrodes on untrimmed hair; and (ii) pre-gelled electrodes after trichotomy. Signals were acquired from the longissimus dorsi muscle at 1 kHz, processed with standardized filtering and rectification, and analyzed in both time and frequency domains. Dry electrodes yielded higher amplitude and Root Mean Square (RMS) values, but slightly lower power spectral density metrics when compared to pre-gelled electrodes. Nevertheless, frequency-domain results were broadly comparable between configurations. Dry electrodes reduce the preparation time, avoid hair clipping, and allow reusability without major signal degradation. While pre-gelled electrodes may still offer marginally superior stability during movement, our results suggest that soft polymeric dry electrodes present a feasible, less invasive, and more sustainable alternative for canine sEMG. These findings support further validation of dry electrodes in clinical populations, particularly for neuromuscular assessment in intervertebral disk disease.

Authors

Institutions

Publication Details

Journal
Animals
Published
2025-10-13
DOI
https://doi.org/10.3390/ani15202959
Primary Topic
Muscle activation and electromyography studies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Are Reusable Dry Electrodes an Alternative to Gelled Electrodes for Canine Surface Electromyography?

João Requicha, João Rafael da Silva Caldeira, Lecino Caldeira, Hugo Silva et al.
Animals
Muscle activation and electromyography studies
article

Are Reusable Dry Electrodes an Alternative to Gelled Electrodes for Canine Surface Electromyography?

João Requicha, João Rafael da Silva Caldeira, Lecino Caldeira, Hugo Silva, C. Peham, Alexandre M. Ribeiro, Inês Brás
article en

Abstract

Despite its increasing use in veterinary rehabilitation, practical constraints-such as skin preparation and single-use electrodes-limit the wider adoption of surface electromyography (sEMG). Having conventional pre-gelled Ag/AgCl electrodes as reference, we made a pioneering comparison of the performance of reusable soft polymeric dry electrodes for recording paraspinal muscle activity in dogs during treadmill walking. Twelve clinically healthy Dachshunds from both genders were evaluated under two conditions, namely: (i) dry electrodes on untrimmed hair; and (ii) pre-gelled electrodes after trichotomy. Signals were acquired from the longissimus dorsi muscle at 1 kHz, processed with standardized filtering and rectification, and analyzed in both time and frequency domains. Dry electrodes yielded higher amplitude and Root Mean Square (RMS) values, but slightly lower power spectral density metrics when compared to pre-gelled electrodes. Nevertheless, frequency-domain results were broadly comparable between configurations. Dry electrodes reduce the preparation time, avoid hair clipping, and allow reusability without major signal degradation. While pre-gelled electrodes may still offer marginally superior stability during movement, our results suggest that soft polymeric dry electrodes present a feasible, less invasive, and more sustainable alternative for canine sEMG. These findings support further validation of dry electrodes in clinical populations, particularly for neuromuscular assessment in intervertebral disk disease.

AnimalsVol. 15(20)
University of Veterinary Medicine Vienna (AT), University of Trás-os-Montes and Alto Douro (PT), Escola Superior de Saúde Egas Moniz (PT), Instituto de Telecomunicações (PT), Instituto Superior Técnico (PT), University of Aveiro (PT)
Openalex Percentile: Top 72%
Muscle activation and electromyography studies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.