Fault section identification method for loop distribution systems in Korea

Radial distributed system (RDS) has the drawback of decreasing line utilization as load variability increases, and this issue has been exacerbated by the recent surge in integration of distribution generation (DG). To address the limitations of the RDS, loop distribution system (LDS) has been introduced. LDS operates with two interconnected distribution lines running simultaneously. Since each line shares the load, they offer the advantage of increasing line utilization and maintaining voltage stability. However, in the event of a fault, the fault current flows in both directions, which creates blind spots for protection coordination when using conventional protection technologies that are designed to handle unidirectional fault currents. This paper presents a case study of LDS introduced in Korea and discusses potential cases of mis-operation in protection coordination, along with solutions to these issues. The study shows how a ground fault occurring in one line of a system with interconnected DGs can cause the circuit breaker (CB) in a non-faulted section to mis-operate. The scenarios and proposed protection methods are verified using the real site examples introduced in Korea.

Authors

Institutions

Publication Details

Journal
IET conference proceedings.
Published
2025-10-14
DOI
https://doi.org/10.1049/icp.2025.1717
Primary Topic
Power Systems and Technologies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Fault section identification method for loop distribution systems in Korea

Linfeng Yu, H. Lee
IET conference proceedings.
Power Systems and Technologies
article

Fault section identification method for loop distribution systems in Korea

Linfeng Yu, H. Lee
article en

Abstract

Radial distributed system (RDS) has the drawback of decreasing line utilization as load variability increases, and this issue has been exacerbated by the recent surge in integration of distribution generation (DG). To address the limitations of the RDS, loop distribution system (LDS) has been introduced. LDS operates with two interconnected distribution lines running simultaneously. Since each line shares the load, they offer the advantage of increasing line utilization and maintaining voltage stability. However, in the event of a fault, the fault current flows in both directions, which creates blind spots for protection coordination when using conventional protection technologies that are designed to handle unidirectional fault currents. This paper presents a case study of LDS introduced in Korea and discusses potential cases of mis-operation in protection coordination, along with solutions to these issues. The study shows how a ground fault occurring in one line of a system with interconnected DGs can cause the circuit breaker (CB) in a non-faulted section to mis-operate. The scenarios and proposed protection methods are verified using the real site examples introduced in Korea.

IET conference proceedings.Vol. 2025(14)
Cheongju University (KR)
Openalex Percentile: Top 71%
Power Systems and Technologies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.